As a substitute for R22, an environmentally friendly zeotropic mixture R417A is often employed. The large glide temperature of the zeotropic mixture R417A could cause capacity and efficiency reductions due to changes in its composition after an isothermal vapor leak/recharge process. It is, therefore, necessary to predict the composition change in R417A under all leak conditions. This paper presents the experimental analysis of the mass composition of R417A in the presence of a 0-50% isothermal vapor leak/recharge in a heat pump water heater. Based on the experimental data, a simple model is proposed to describe the composition change in R417A for various leaks and recharge scenarios. The effect of composition change in the performance of a heat pump water heater is also dealt with. Experimental results show that the composition changes in R417A increase as ambient temperature decreases. Isothermal vapor leaks have a great effect on the composition of R417A and the performance of a heat pump water heater at lower temperatures. It is also found that when the ambient temperature is higher than 7℃ with a 10% leak and R417A recharge, there is almost no difference in the performance of the plant with respect to the original state except that the compressor discharge temperature is lower.
机译:作为R22的替代品,经常使用环保的共沸混合物R417A。共沸混合物R417A的大滑行温度可能会导致容量和效率降低,这是由于等温蒸气泄漏/补给过程后其组成发生了变化。因此,有必要在所有泄漏条件下预测R417A中的成分变化。本文介绍了在热泵热水器中存在0-50%等温蒸气泄漏/补给的情况下R417A的质量组成的实验分析。根据实验数据,提出了一个简单的模型来描述R417A在各种泄漏和补给情况下的成分变化。还解决了成分改变对热泵热水器性能的影响。实验结果表明,R417A的组成变化随环境温度的降低而增加。等温蒸气泄漏对R417A的成分和较低温度下的热泵热水器的性能有很大影响。还发现,当环境温度高于7℃且泄漏率为10%且R417A补给时,除压缩机排气温度较低外,与原始状态相比,设备的性能几乎没有差异。

著录项

  • 来源
    《Journal of Energy Resources Technology》 |2009年第4期|042401.1-042401.5|共5页
  • 作者单位

    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P.R.C.;

    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P.R.C.;

    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P.R.C.;

    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P.R.C.;

    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, P.R.C.;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    heat pump; R417A; leakage; ternary mixture;