首页> 外文期刊>Journal of dairy science >False-positive outcome and drug residue in milk samples over withdrawal times
【24h】

False-positive outcome and drug residue in milk samples over withdrawal times

机译:停药期间假奶制品中的假阳性结果和药物残留

获取原文
获取原文并翻译 | 示例
           

摘要

This study was conducted to identify false-positive outcomes and drug residues in milk samples over withdrawal times and to determine whether the positive results were caused by drug residues or natural inhibitors. A total of 73 milk samples over withdrawal times after the last intramammary infusion were collected from each treated quarter of cows and tested using the Delvotest SP assay. Reading time was 150, 165, and 180 min, and results of samples were recorded according to the color of the well containing the control milk sample. There were 24, 20, and 12 positive samples at the reading times of 150, 165, and 180 min, respectively. All 24 positive milk samples were heated at 82 degrees C for 5 min and retested to verify that the positive results were caused by drug residues or natural inhibitors. Twenty-one samples that exhibited positive results were negative after heat treatment, and drug residues were not identified by LacTek and Charm tests. However, 3 samples that exhibited positive results from heat treatment of 82 degrees C were positive for drugs. In our study, most positive results (89%) in the milk samples over withdrawal times were false-positive results by natural inhibitors. Moreover, the heat treatment is a fast, simple, and inexpensive method to remove false-positive results and has no effect on positive samples containing drugs. We suggest that heat treatment before screening tests is an effective way to reduce false-positive results in the milk samples.
机译:进行这项研究的目的是确定停药期间假奶样品中的假阳性结果和药物残留,并确定阳性结果是由药物残留还是天然抑制剂引起的。在最后一次乳房内输注后,在撤离时间内总共收集了73个牛奶样品,并从每个处理过的四分之一的母牛中收集,并使用Delvotest SP测定法进行了测试。读取时间为150、165和180分钟,并根据包含对照乳样品的孔的颜色记录样品的结果。在150、165和180分钟的读取时间分别有24、20和12个阳性样品。将所有24个阳性乳样品在82摄氏度下加热5分钟,然后重新测试以验证阳性结果是由药物残留物或天然抑制剂引起的。在热处理后,有21个样品显示阳性结果为阴性,并且LacTek和Charm测试未鉴定出药物残留。但是,有3个样品在82摄氏度的热处理中均显示出阳性结果,而这些药物均为阳性。在我们的研究中,在停药期间,牛奶样品中大多数阳性结果(89%)是天然抑制剂的假阳性结果。而且,热处理是去除假阳性结果的快速,简单且廉价的方法,并且对含有药物的阳性样品没有影响。我们建议在筛选试验之前进行热处理是减少牛奶样品中假阳性结果的有效方法。

著录项

  • 来源
    《Journal of dairy science》 |2005年第3期|p.908-913|共6页
  • 作者

    Kang JH; Jin JH; Kondo F;

  • 作者单位

    Department of Veterinary Public Health, Faculty of Agriculture, Miyazaki University, Kibanadai-Nishi, Gakuen, Miyazaki-shi 889-2192, Japan.;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 乳品加工工业;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号