In this paper, overstrength, ductility and response modification factor of Buckling Restrained Braced frames were evaluated. To do so, buildings with various stories and different bracing configuration including diagonal, split X, chevron (V and Inverted V) bracings were considered. Static pushover analysis, nonlinear incremental dynamic analysis and linear dynamic analysis have been performed using Opensees software. The effects of some parameters influencing response modification factor, including the height of the building and the type of bracing system, were investigated. In this article seismic response modification factor for each of bracing systems has been determined separately and tentative values of 8.35 and 12 has been suggested for ultimate limit state and allowable stress design methods.
机译:本文评估了屈曲约束支撑框架的超强度,延展性和响应修正系数。为此,考虑了具有不同楼层和不同支撑配置的建筑物,包括对角线,X分割,人字形(V和反向V)支撑。已使用Opensees软件执行了静态推覆分析,非线性增量动态分析和线性动态分析。研究了一些影响响应修正因子的参数的影响,包括建筑物的高度和支撑系统的类型。在本文中,已经分别确定了每个支撑系统的地震响应修正系数,并为极限极限状态和容许应力设计方法建议了暂定值8.35和12。