Experimental and numerical studies into the structural behaviour of reinforced concrete columns confined by circular steel tubes after exposure to standard fire conditions are presented. These elements differ from conventional concrete-filled steel tubular (CFST) columns in that breaks in continuity are present at the member ends, which limit the longitudinal stresses in the steel and maximise the level of confinement afforded to the concrete through the generation of hoop stresses in the tube. The temperature distributions in the specimens were measured during the heating and cooling phases, while the load-displacement relationships and longitudinal and transverse strains in the steel tube were recorded during the subsequent compressive tests. 3D finite element (FE) models were also developed using the program ABAQUS to investigate the post-fire performance of circular steel tube confined reinforced concrete (CSTCRC) columns, including both heat transfer and stress analyses. The FE models were used to identify the influences of key parameters on the residual capacity of CSTCRC columns, following exposure to the ISO-834 standard fire. The considered parameters included heating time, cross-sectional dimensions, strength of the materials, steel tube to concrete area ratio and ratio of reinforcement. Finally, a design method was proposed for predicting the residual load bearing capacity and compressive stiffness of CSTCRC columns after standard fire exposure.
机译:给出了在暴露于标准火灾条件下由圆形钢管约束的钢筋混凝土柱结构性能的实验和数值研究。这些元素与传统的钢管混凝土(CFST)立柱的不同之处在于,在构件端部存在连续性断裂,这限制了钢中的纵向应力,并通过产生环向应力最大化了对混凝土的约束水平在管中。在加热和冷却阶段测量了样品的温度分布,同时在随后的压缩试验中记录了钢管的载荷-位移关系以及纵向和横向应变。还使用ABAQUS程序开发了3D有限元(FE)模型,以研究圆形钢管承压钢筋混凝土(CSTCRC)柱的火灾后性能,包括传热和应力分析。在暴露于ISO-834标准火灾后,使用FE模型来识别关键参数对CSTCRC色谱柱剩余容量的影响。所考虑的参数包括加热时间,横截面尺寸,材料强度,钢管与混凝土的面积比以及配筋率。最后,提出了一种设计方法,用于预测标准火灾后CSTCRC柱的残余承载力和抗压刚度。

著录项

  • 来源
    《Journal of Constructional Steel Research》 |2014年第11期|82-103|共22页
  • 作者单位

    Key Lab of Structures Dynamic Behavior and Control (Harbin Institute of Technology), Ministry of Education, Heilongjiang, Harbin 150090, China ,Department of Civil and Environmental Engineering, South Kensington Campus, Imperial College London, SW7 2AZ, UK ,School of Civil Engineering, Harbin Institute of Technology, Heilongjiang, Harbin 150090, China;

    Department of Civil and Environmental Engineering, South Kensington Campus, Imperial College London, SW7 2AZ, UK;

    Key Lab of Structures Dynamic Behavior and Control (Harbin Institute of Technology), Ministry of Education, Heilongjiang, Harbin 150090, China ,School of Civil Engineering, Harbin Institute of Technology, Heilongjiang, Harbin 150090, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Circular steel tube confined reinforced concrete; Compressive stiffness; Post-fire; Residual capacity; Thermal distribution;

    机译:圆形钢管承压钢筋混凝土;抗压刚度;射击后剩余容量;热分布;