摘要

This study addresses the nonlinear seismic responses of ordinary moment frame building upgraded with a series of passive protective systems. To this, friction damper (FD) as an energy dissipation device and lead rubber bearing (LRB), friction pendulum beating (FPB), and high damping rubber bearing (HDRB) as base isolators were considered. The effectiveness of the isolation systems together with the dampers was investigated comparatively. For this purpose, eight different cases were taken into account. The first case contains a five storey steel ordinary moment frame considered as fixed-base (FB), the other four cases are the single use of FD, LRB, FPB, and HDRB in such frame, and the last three cases include the upgrading of the frame with the combination of FD with each of the base isolation systems. They are modelled using a finite element program, and evaluated by the nonlinear time history analyses in which seven ground motion records were adopted. The seismic performance of the passive protective systems was evaluated by the engineering demand parameters such as storey displacement, bearing displacement, relative displacement, roof drift ratio, interstorey-drift ratio, absolute acceleration, base shear, base moment, hysteretic curve, and energy dissipation. One of the main outcomes of this study was that single protective system could not always satisfy fully operational performance level, while the combined systems of the base isolation with friction damper effectively achieved for the case study frame. Furthermore, the results showed that the combined systems were capable of limiting the inter-storey drift without increasing the absolute accelerations. (C) 2020 Elsevier Ltd. All rights reserved.
机译:本研究解决了用一系列被动保护系统升级的普通时刻框架建筑的非线性地震反应。为此,考虑了摩擦阻尼器(FD)作为能量耗散装置和铅橡胶轴承(LRB),摩擦摆率(FPB)和高阻尼橡胶轴承(HDRB)作为基部隔离器。相对调查隔离系统与阻尼器的有效性。为此目的,考虑了八种不同的案例。第一种案例包含一个五层钢普通时刻框架被认为是固定基础(FB),另外四个案例是单一使用FD,LRB,FPB和HDRB在此帧中,最后三种情况包括升级具有FD的组合的帧与每个基本隔离系统。它们使用有限元程序进行建模,并由非线性时间历史分析评估,其中采用了七种地面运动记录。通过工程需求参数如岩石位移,轴承位移,相对位移,屋顶漂移比,间隙 - 漂移比,绝对加速,基本剪切,基本剪切,基板矩,滞后曲线和能量耗散的工程需求参数评估了被动需求参数的地震性能。 。本研究的主要结果之一是单一保护系统并不总是满足完全运行的性能水平,而基本隔离的组合系统与案例研究框架有效地实现了摩擦阻尼器。此外,结果表明,组合的系统能够在不增加绝对加速度的情况下限制跨度漂移的漂移。 (c)2020 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号