A procedure coupling acid decomposition and precipitation, using inductively coupled plasma optical emission spectrometry (ICP-OES) is proposed for the determination of Cl, Br and I in milk samples. During the mineralization process in closed and open vessels (microwave ovens), anions are precipitated as salts of low solubility products (AgCl, AgBr and AgI). After separation from digestate solution, precipitates are dissolved with ammonia resulting in a 20% v/v solution. The final solution was directly introduced into the ICP-OES without any damage to the sample introduction system and with no severe spectral interference. Three biological reference materials were used to validate the methodology: Non-Fat Milk Powder SRM 1549 from NIST, Skim Milk Powder RM-151 from BCR and Whole Egg Powder RM 8415, also from NIST. The limits of detection (3sigma(b)/s) for Cl, Br and I in the solid sample were 30, 40 and 280 mug g(-1) for the closed vessel microwave oven, and 15, 20 and 40 mg g(-1) for the open vessel microwave oven, respectively. Relative standard deviations, considering five replicates of sample submitted to the proposed methodology, were 1% for Cl and Br, and 2% for I, when a closed vessel microwave was used. The results for Cl were in good agreement with the certified values (90% confidence level). For Br, recoveries ranged from 87 to 104% for closed vessel microwave oven and from 90 to 102% for open vessel microwave oven. As for I, recoveries ranged from 85 to 98% with a closed vessel microwave oven. Accurate results for determinations in certified materials and good recoveries demonstrated the efficiency of the procedure. [References: 29]
机译:提出了一种使用电感耦合等离子体发射光谱法(ICP-OES)耦合酸分解和沉淀的方法来测定牛奶样品中的Cl,Br和I。在封闭和开放容器(微波炉)中进行矿化过程中,阴离子以低溶解度​​产物(AgCl,AgBr和AgI)的盐形式沉淀。从消化液中分离出来后,沉淀物会被氨水溶解,形成20%v / v的溶液。将最终溶液直接引入ICP-OES中,而不会损坏样品引入系统,也不会造成严重的光谱干扰。使用三种生物参考材料来验证该方法:NIST的脱脂奶粉SRM 1549,BCR的脱脂奶粉RM-151和NIST的全蛋粉RM 8415。密闭容器微波炉中固体样品中Cl,Br和I的检出限(3sigma(b)/ s)为30、40和280杯子g(-1),而密闭容器微波炉的检测极限为15、20和40 mg g( -1)分别用于开放式容器微波炉。当使用密闭容器微波时,考虑到提交给拟议方法的五个重复样品,相对标准偏差为Cl和Br为1%,I为2%。 Cl的结果与认证值(90%置信度)非常吻合。对于Br,密闭容器型微波炉的回收率范围为87%至104%,而敞口容器型微波炉的回收率范围为90%至102%。至于I,使用密闭容器微波炉的回收率在85%到98%之间。准确的结果可通过认证的材料进行测定,并具有良好的回收率,证明了该过程的效率。 [参考:29]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号