首页> 外文期刊>International Orthopaedics >Observer reliability in evaluating pedicle screw placement using computed tomography
【24h】

Observer reliability in evaluating pedicle screw placement using computed tomography

机译:使用计算机断层扫描评估椎弓根螺钉放置的观察者可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Pedicle screw insertion in spinal surgery is a demanding technique with potential risks to neurological structures, for example, within the spinal canal. Assessing screw placement in clinical practice has been performed using plain radiographs and/or mainly axial computed tomography (CT) images. Screw placement using CT image reconstructions in multiple planes has been described, but its reliability has yet to be studied. This study aimed at addressing the clinical issue of interobserver and intraobserver reliability in the use of axial and coronal CT images for the assessment of pedicle screw placement. Fifty nine pedicle screws were studied by two experienced radiologists on two separate occasions. Screw placement was classified as “in”, “out” or “questionable”. On average, 88% and 92% of the screws were classified as “in” by the first and second radiologist, respectively. Intraobserver agreement strength was almost perfect for both observers using either axial or coronal images. Interobserver agreement strength was almost perfect (axial) and substantial (coronal) in the first reading and substantial (axial, coronal) in the second reading. Assessing screw placement in more than one CT imaging plane is not only useful but reliable. Routine use may enhance reporting quality of screw placement by surgeons and radiologists.
机译:脊柱外科手术中椎弓根螺钉的插入是一项苛刻的技术,会对神经结构(例如,在椎管内)产生潜在的风险。已经使用普通的X射线照片和/或主要是轴向计算机断层扫描(CT)图像对临床实践中的螺钉位置进行了评估。已经描述了在多个平面中使用CT图像重建进行螺钉放置的方法,但是其可靠性尚待研究。这项研究旨在解决使用轴向和冠状CT图像评估椎弓根螺钉放置时观察者间和观察者内可靠性的临床问题。两名经验丰富的放射科医生分别在两个不同的场合研究了59个椎弓根螺钉。螺钉放置分为“入”,“出”或“可疑”。平均而言,第一和第二位放射科医生分别将88%和92%的螺钉归类为“ in”。对于使用轴向图像或冠状图像的两个观察者来说,观察者内部的一致性强度几乎是完美的。观察者之间的一致性强度在第一次阅读中几乎是完美的(轴向)和显着(冠状),在第二次阅读中是显着(轴向,冠状)。评估螺钉在多个CT成像平面中的放置不仅有用而且可靠。常规使用可提高外科医生和放射科医生报告螺钉放置的质量。

著录项

  • 来源
    《International Orthopaedics》 |2007年第4期|531-536|共6页
  • 作者单位

    Department of Orthopedics Hôpital Orthopédique de la Suisse Romande Avenue Pierre-Decker 4 CH-1005 Lausanne Switzerland;

    Department of Radiology Centre Hospitalier Universitaire Vaudois Lausanne Switzerland;

    Department of Radiology Centre Hospitalier Universitaire Vaudois Lausanne Switzerland;

    Department of Orthopedics Hôpital Orthopédique de la Suisse Romande Avenue Pierre-Decker 4 CH-1005 Lausanne Switzerland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng