The treatment of fractures of the distal third of the tibia has evolved with the development of improved imaging and surgical techniques. The outcome of treatment using conventional fixation is poor. We report a study on indirect reduction in 26 patients. All cases achieved radiological union and full weight bearing. The good to excellent results suggest that this method should be considered in metaphyseal fractures where intra-medullary nails are not suitable.
机译:随着改进的成像和手术技术的发展,胫骨远端三分之一骨折的治疗方法也得到了发展。使用常规固定的治疗效果不佳。我们报告了一项间接减少26例患者的研究。所有病例均达到放射学结合和负重。良好至优异的结果表明,这种方法应在不适合使用髓内钉的干meta端骨折中考虑。