摘要

In this paper, an attempt has been made to reduce the harmonics generated into the stator terminals due to non-linear load connected at the grid side of a doubly fed induction generator (DFIG)-wind turbine system. Also, the stator voltage profile is regulated by injecting appropriate series voltage into the line, using series grid side converter (SGSC), to maintain its desire value during symmetrical/asymmetrical grid faults. A closed-loop selective harmonic compensation technique-based control strategy is considered for SGSC. The MATLAB®/Simulink® platform is used to simulate the study system and analyse the simulation results. It is noticed that the SGSC with its control scheme can be enough capable for maintaining the stator voltage of DFIG during grid sag, and reducing the undesirable effects and harmonic content at the stator terminals due to the non-linear load.
机译:在本文中,已尝试减少由于在双馈感应发电机(DFIG)-风力涡轮机系统的电网侧连接的非线性负载而在定子端子中产生的谐波。同样,通过使用串联电网侧变流器(SGSC)向线路中注入适当的串联电压来调节定子电压曲线,以在对称/非对称电网故障期间维持其期望值。 SGSC考虑了基于闭环选择性谐波补偿技术的控制策略。 MATLAB®/Simulink®平台用于模拟研究系统并分析模拟结果。注意到,SGSC及其控制方案足以在电网突降期间保持DFIG的定子电压,并减少由于非线性负载而在定子端子上产生的不良影响和谐波含量。