首页> 外文期刊>International Journal of Heat and Mass Transfer >Experimental shell-side heat transfer and pressure drop in gas flow for spiral-wound LNG heat exchanger
【24h】

Experimental shell-side heat transfer and pressure drop in gas flow for spiral-wound LNG heat exchanger

机译:螺旋缠绕式LNG换热器的实验壳侧传热和气流中的压降

获取原文
获取原文并翻译 | 示例
           

摘要

A test plant has been constructed for measurements of local heat-transfer coefficients and frictional pressure drops on the shell side of spiral-wound LNG heat exchangers. Measurements have been performed with gas flow, liquid film flow and two-phase shear flow. This paper focuses on the measurements and the results from the gas flow measurements. 221 gas flow heat-transfer measurements and 80 gas flow frictional pressure drop measurements have been performed at a Re-number range of 5000-170000 with nitrogen, methane, ethane and methane/ethane mixture as test fluids.
机译:在螺旋缠绕式LNG换热器的壳侧,已经建造了一个测试装置,用于测量局部传热系数和摩擦压降。用气体流量,液膜流量和两相剪切流量进行了测量。本文着重于测量和气体流量测量的结果。在氮气,甲烷,乙烷和甲烷/乙烷混合物作为测试流体的Re-number范围内,进行了221次气流传热测量和80次气流摩擦压降测量。