首页> 外文期刊>International Journal of Heat and Mass Transfer >Investigation on the performance and optimization of heat pump water heater with wrap-around condenser coil
【24h】

Investigation on the performance and optimization of heat pump water heater with wrap-around condenser coil

机译:环绕式冷凝器盘管热泵热水器的性能及优化研究

获取原文
获取原文并翻译 | 示例
           

摘要

A numerical investigation on the performance of heat pump water heater (HPWH) with wrap-around condenser coil was carried out. In this study, a coupled model was developed to simulate the static energy storage process of HPWH, which consisted of a multi-heat flux CFD model to describe the flow and heat transfer in water tank and a vapor-compression system model established in MATLAB to simulate the system operation characteristics. Heat flux in superheated steam, two-phase flow, and sub cooled liquid regions of the condenser was obtained from the system model as boundary conditions of water tank model. The simulation results of the coupled model were in good agreement with experimental results. Heat transfer coefficient, COP and water temperature distribution of variable-pitch and constant-pitch coil were obtained by simulation. The results indicated that the heat transfer coefficient and average COP of variable-pitch coil were increased by 21.91% and 10.75% respectively, compared with constant-pitch coil. In addition, it was found that by appropriately reducing spiral pitch and coil diameter, average water temperature was increased by about 1 degrees C and maximum temperature difference in the vertical direction was no more than 7.50 degrees C. This work provides meaningful guidance for performance optimization of heat pump water heater. (C) 2019 Elsevier Ltd. All rights reserved.
机译:对带有缠绕式冷凝器盘管的热泵热水器(HPWH)的性能进行了数值研究。在这项研究中,开发了一个耦合模型来模拟HPWH的静态能量存储过程,该模型由描述水箱中流动和传热的多热通量CFD模型和在MATLAB中建立的蒸汽压缩系统模型组成,以模拟系统运行特性。从系统模型中获得冷凝水过热蒸汽,两相流和冷凝器的过冷液体区域中的热通量作为水箱模型的边界条件。耦合模型的仿真结果与实验结果吻合良好。通过仿真得到了变螺距和定螺距线圈的传热系数,COP和水温分布。结果表明,与定距线圈相比,变螺距线圈的传热系数和平均COP分别提高了21.91%和10.75%。此外,发现通过适当减小螺旋螺距和线圈直径,可使平均水温提高约1摄氏度,垂直方向的最大温差不超过7.50摄氏度。这项工作为性能优化提供了有意义的指导。热泵热水器。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有