Liquid chromatography coupled to tandem mass spectrometry with a triple quadrupole analyser was used to determine selected (medium) polar organic pollutants—isoproturon, diuron and pentachlorophenol, as the herbicides sirnazine, atrazine, terbuthilazine, alachlor, and metolachlor—in treated water from urban solid-waste leachates. Two millilitres of water was preconcentrated by on-line trace enrichment (solid-phase extraction liquid chromatography) which allowed rapid analysis, but still with a satisfactory sensitivity, as the limits of quantification were 0.05 μgL~(-1), while the limits of detection were in the range of 0.001-0.01 μgL~(-1). Confirmation of the identity of compounds was ensured by the use of two tandem mass spectrometry transitions. Moreover, a study of matrix effects was thoroughly investigated by applying the developed procedure to different ground and surface waters. A simple dilution of the water sample with high-performance-liquid-chromatography-grade water was sufficient to minimize and/or remove this undesirable effect in all water samples tested, this approach being feasible due to the excellent sensitivity of the method.
机译:使用液相色谱与三重四极杆质谱仪进行串联质谱联用,确定了城市固体污水中除草剂西拉嗪,阿特拉津,特布他拉嗪,丙草胺和甲草胺的除草剂西拉嗪,阿特拉津,特布他拉嗪,丙草胺和甲草胺,从而确定了选定的(中等)极性有机污染物,如异丙隆,杜隆和五氯苯酚。废物渗滤液。通过在线痕量富集(固相萃取液相色谱)对2毫升水进行预浓缩,可以进行快速分析,但仍具有令人满意的灵敏度,因为定量限为0.05μgL〜(-1),而检测范围为0.001-0.01μgL〜(-1)。通过使用两个串联质谱跃迁来确保化合物身份的确认。此外,通过将开发的程序应用于不同的地下水和地表水,彻底研究了基质效应。用高性能液相色谱级的水对水样品进行简单稀释就足以最小化和/或消除所有测试水样品中的不良影响,由于该方法具有出色的灵敏度,因此该方法是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号