Several configurations of receiving disks and diffusion membranes were tested for monitoring mercury and organotin compounds (monobutyltin, dibutyltin, tributyltin, and triphenyltin) in water with a passive sampler. This passive sampler is based on the diffusion of these compounds through a specific diffusion-limiting membrane and their subsequent accumulation on a specific receiving phase, all materials being commercially available. The proposed sampler for inorganic mercury comprises a 47-mm Empore™ chelating disk as receiving phase and polyethersulfone as diffusion membrane. For monitoring organotins, the receiving phase is a 47-mm Empore™ C_(18) disk, and the diffusion membrane is cellulose acetate. ICP-MS and GC-ICPMS/GC-FPD were used for inorganic mercury and the organotins analysis, respectively. The effects of environmental variables such as pH and salinity that could influence accumulation of test substances in receiving phase were studied. Linear uptake for all compounds was observed for at least 14 days of exposure at a constant aqueous analyte concentration in a flow-through system under controlled conditions of temperature, turbulence, and analyte concentration. Compound-specific sampling rates at 11℃ and simulated water turbulence of 40 cm s~(-1) varied between 0.018 and 0.137 Ld~(-1). Compounds collected by the sampler exhibited detection limits ranging between 0.7 and 5.9 ngL~(-1). The feasibility of using these samplers in the field was tested in a polluted commercial harbour. The behaviour of the samplers to monitor target compounds was compared with those obtained from spot samples of water taken throughout the field deployment period. Data from laboratory studies and field trial support the feasibility of these samplers to measure the freely dissolved fraction of these important target analytes in water.
机译:测试了接收盘和扩散膜的几种配置,以使用无源采样器监测水中的汞和有机锡化合物(单丁基锡,二丁基锡,三丁基锡和三苯基锡)。该无源采样器基于这些化合物通过特定的扩散限制膜的扩散以及它们随后在特定的接收相上的积累,所有材料都是可商购的。建议的无机汞采样器包括一个47毫米Empore™螯合盘作为接收相,而聚醚砜则作为扩散膜。为了监测有机锡,接收阶段是47毫米Empore™C_(18)盘,扩散膜是醋酸纤维素。 ICP-MS和GC-ICPMS / GC-FPD分别用于无机汞和有机锡的分析。研究了pH值和盐度等环境变量对接收阶段受试物质积累的影响。在恒定的含水分析物浓度下,在受控的温度,湍流和分析物浓度条件下,在流通系统中以恒定的含水分析物浓度观察到所有化合物的线性吸收至少14天。在11℃和40 cm s〜(-1)的模拟水湍流下,化合物的特定采样率在0.018和0.137 Ld〜(-1)之间变化。采样器收集到的化合物的检出限在0.7到5.9 ngL〜(-1)之间。在污染的商业港口中测试了在野外使用这些采样器的可行性。将采样器监测目标化合物的行为与从现场部署整个过程中抽取的现场水样获得的行为进行了比较。来自实验室研究和现场试验的数据支持了这些采样器测量这些重要目标分析物在水中的自由溶解分数的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号