Determination of Hg(II) ions in water samples by a novel Hg(II) sensor, based on calix[4]arene derivative

机译:基于杯[4]芳烃衍生物的新型Hg(II)传感器测定水样中的Hg(II)离子

获取原文
获取原文并翻译 | 示例
           

摘要

A PVC membrane electrode for Hg(II) ions, based on a new cone shaped calix[4]arene (L) as a suitable ionophore was constructed. The sensor exhibits a linear dynamic in the range of 1.0 × 10~(-6)-1.0 × 10~(-1) M, with a Nernstian slope of 29.4±0.4mV decade~(-1), and a detection limit of 4.0 × 10~(-7)M. The response time is quick (less than 10 s), it can be used in the pH range of 1.5-4, and the electrode response and selectivity remained almost unchanged for about 2 months. The sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, and some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Hg~(2+) ions with potassium iodide, and the direct determination of mercury content of amalgam alloy and water samples.
机译:基于一种新的锥形杯[4]芳烃(L)作为合适的离子载体,构建了用于汞(II)离子的PVC膜电极。该传感器在1.0×10〜(-6)-1.0×10〜(-1)M的范围内表现出线性动态,能斯特斜率为29.4±0.4mV·十进位(-1),检测极限为4.0×10〜(-7)米响应时间快(小于10 s),可以在1.5-4的pH范围内使用,电极响应和选择性在大约2个月内几乎保持不变。该传感器对大多数碱金属,碱土金属以及一些过渡金属和重金属离子具有相对较好的选择性。它已成功地用作指示电极,用碘化钾电位滴定Hg〜(2+)离子,以及直接测定汞合金和水样中的汞含量。