首页> 外文期刊>International journal of environmental analytical chemistry >Electrochemical flow injection immunoassay for cortisol using magnetic microbeads
【24h】

Electrochemical flow injection immunoassay for cortisol using magnetic microbeads

机译:磁微珠对皮质醇的电化学流动注射免疫测定

获取原文
获取原文并翻译 | 示例
           

摘要

We developed a novel flow injection assay for cortisol based on competitive immunologic reactions, magnetic separation, and electrochemical measurement. The proposed flow assay system was composed of two reaction units. An anti-cortisol antibody was immobilised on magnetic beads and injected into the reaction coil of a competitive reaction unit with a blood sample and a specific quantity of acetylcholinesterase-labelled cortisol (cort-AChE). After reacting in the reaction coil, the sample was separated magnetically using a neodymium magnet. The cort-AChE was detached from the magnetic beads and transferred into the enzyme reaction unit with acetylthiocholine (ATCh). ATCh was hydrolysed by the cort-AChE to produce thiocholine. The thiocholine was quantified downstream by electrochemical detection using a Pt-Ir electrode. The performance of the proposed flow assay system was optimised under the following conditions: pH 7.5, temperature 25°C, flow rate 170μlmin-1, ATCh concentration in the substrate buffer 5mmolL-1. The output current was well correlated with the concentration of the cortisol standard solution (range: 7.8-500 pgmL-1). The results obtained using the proposed flow method were compared with those obtained using conventional ELISA (correlation coefficient 0.9585 [y=-0.9797+ 1.173(×),n = 11]). These findings suggest that the EFIIA system can be used to analyse cortisol in fish plasma samples.
机译:我们基于竞争性免疫反应,磁分离和电化学测量开发了一种新型的皮质醇流动注射测定法。拟议的流动分析系统由两个反应单元组成。将抗皮质醇抗体固定在磁珠上,并与血液样本和特定量的乙酰胆碱酯酶标记的皮质醇(cort-AChE)注入竞争性反应单元的反应线圈中。在反应线圈中进行反应后,使用钕磁铁将样品磁性分离。将cort-AChE与磁珠分离,并与乙酰硫胆碱(ATCh)一起转移到酶反应单元中。 ATCh被cort-AChE水解产生硫代胆碱。通过使用Pt-Ir电极的电化学检测在下游对硫代胆碱进行定量。在以下条件下优化了拟议的流动分析系统的性能:pH 7.5,温度25°C,流速170μlmin-1,底物缓冲液中ATCh浓度5mmolL-1。输出电流与皮质醇标准溶液的浓度密切相关(范围:7.8-500 pgmL-1)。使用提议的流动方法获得的结果与使用常规ELISA获得的结果进行了比较(相关系数0.9585 [y = -0.9797 + 1.173(×),n = 11])。这些发现表明EFIIA系统可用于分析鱼血浆样品中的皮质醇。

著录项

  • 来源
  • 作者单位

    Faculty of Marine Science, Tokyo University of Marine Science and Technology 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Technology, Tokyo University of Marine Science and Technology 2-1-6 Etchujima, Koutou-ku, Tokyo, 135-8533, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan;

    Faculty of Marine Science, Tokyo University of Marine Science and Technology 4-5-7 Konan, Minato-ku, Tokyo 108-8477, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    cortisol; fia; magnetic microbeads; immunoassay; fish; monitoring;