A simple and sensitive method for the determination of ultra trace amounts of U(VI) and Th(IV) ions by spectrophotometric method after solid-phase extraction on a new extractant-impregnated resin (EIR) has been reported. The new EIR was synthesised by impregnating a weakly polar polymeric adsorbent, Amberlite XAD-7, with titan yellow (TY) as extractant. The analytical method is based on the simultaneous adsorption of analyte ions in a mini-column packed with TY/XAD-7 and performing sequential elution with 0.5% (w/v) Na2CO3 for uranium and 2.0M HCl for thorium. The influences of the analytical parameters including pH, salting out agent and sample volume were investigated. The interference effects of foreign ions on the retention of the analyte ions were also explored. The limits of detection for U(VI) and Th(IV) were as low as 50 and 25ngL(-1), respectively. Relative standard deviations (n=7) for U(VI) and Th(IV) were 3.1% and 2.9%, respectively. The method was successfully applied to the determination of ultra trace amounts of U(VI) and Th(IV) in different real matrices including industrial wastewater samples and environmental waters. The proposed method was validated using three certified reference materials and the results were in good agreement with the certified values.
机译:报道了一种在新的浸有萃取剂的树脂(EIR)上进行固相萃取后,通过分光光度法测定超痕量U(VI)和Th(IV)离子的简单灵敏方法。通过用钛黄(TY)作为萃取剂浸渍弱极性聚合物吸附剂Amberlite XAD-7来合成新的EIR。该分析方法是基于分析物离子在装有TY / XAD-7的微型柱中的同时吸附,并用0.5%(w / v)的Na2CO3铀和M 2.0M HCl进行顺序洗脱。研究了pH,盐析剂和样品量等分析参数的影响。还探讨了外来离子对被分析物离子保留的干扰作用。 U(VI)和Th(IV)的检出限分别低至50和25ngL(-1)。 U(VI)和Th(IV)的相对标准偏差(n = 7)分别为3.1%和2.9%。该方法已成功地用于测定工业废水样品和环境水等不同实际基质中超痕量的U(VI)和Th(IV)。使用三种认证的参考材料对所提出的方法进行了验证,结果与认证值高度吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号