摘要

An innovative one-side actuating piezoelectric micropump (OAPCP-micropump), which is combined with a 45 mm×28 mm×4 mm cold plate chamber, has been developed to drive liquid in a cooling system for a laptop. The results show that the shape and the numbers of the fins inside the cold plate chamber have strong effects on the pressure drops and flow profiles. The fluid in the pump chamber may impinge on the fins and increase the heat dissipation rate due to the oscillation by the actuator. The measured maximum flow rate of the OAPCP-micropump is 4.1 ml/s, and its maximum pump head reaches 9807 Pa. The new cooling system with an OAPCP-micropump design shows a stable performance on total thermal resistance due to the high flow rate.
机译:已开发出一种创新的单边致动压电微型泵(OAPCP-微型泵),该微型泵与45 mm×28 mm×4 mm的冷板腔室相结合,用于驱动笔记本电脑冷却系统中的液体。结果表明,冷板腔内翅片的形状和数量对压降和流场有很大影响。由于执行器的振荡,泵室内的流体可能会撞击到散热片上并增加散热率。 OAPCP微型泵的最大测得流量为4.1 ml / s,最大泵头达到9807 Pa。采用OAPCP微型泵设计的新型冷却系统由于流速高,对总热阻表现出稳定的性能。