In this work, the widely used chevron corrugated-plate heat exchanger was simulated, and the three-dimensional temperature, pressure, and velocity fields were obtained. From the temperature field we can see that in the first zone, the temperature gradient increases gradually and get the maximum; in the central of the flow, the temperature gradient becomes smaller again. The highest temperature appears around the upper port, while the lowest temperature appears in the cold fluid inflow around the lower port. From the pressure field, we can see that the fluid pressure is gradually reduced along the flow direction. From the flow field, no matter the fluid inflows or outflows the port, there is a marked "dead zone" departed from the corrugated side of the port, where the fluid flow rate is very low. The fluid flows along the side of the port and appears a minor's "bias" (uneven-distributed) phenomenon. Meanwhile, it can be seen that a large number of contact points are distributed in the chevron corrugated-plate heat exchanger. In addition, the simulated results are compared with the experimental values and found that trends of the outside temperature are consistent with those of pressure drop, and experimental values were similar to those of simulated values.
机译:在这项工作中,模拟了广泛使用的V形波纹板式换热器,并获得了三维温度,压力和速度场。从温度场中我们可以看到,在第一个区域中,温度梯度逐渐增大并达到最大值。在流动的中心,温度梯度再次变小。最高温度出现在上部端口附近,而最低温度出现在下部端口周围的冷流体流入中。从压力场可以看出,流体压力沿流动方向逐渐减小。从流场来看,无论流体流入或流出端口,都存在明显的“死区”,该“死区”是从端口的波纹面离开的,流体的流速非常低。流体沿端口的侧面流动,并出现未成年人的“偏斜”(不均匀分布)现象。同时,可以看出在人字形波纹板式热交换器中分布有大量的接触点。此外,将模拟结果与实验值进行比较,发现外部温度的趋势与压降的趋势一致,并且实验值与模拟值相似。

著录项

  • 来源
    《Letters in heat and mass transfer》 |2010年第8期|p.1008-1014|共7页
  • 作者单位

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

    Institute of Refrigeration and Cryogenics, State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    chevron corrugated-plate heat exchanger; temperature field; pressure field; flow field; contact point;