An accurate direct measurement of ac current that avoids complex and time-consuming ac–dc current transfer measurements by directly measuring the ac voltage drop of coaxial current shunts is described. Evaluation of custom-developed coaxial current shunts for long-term drift, self-heating effects, and loading using a commercial ac voltmeter is presented. By correcting only the shunts'' long-term drift, direct ac current measurement uncertainties below 55 $muhbox{A/A}$ are attained in the frequency range of 20 Hz–30 kHz and for currents ranging from 100 mA up to 10 A.
机译:本文介绍了一种精确的交流电流直接测量方法,该方法通过直接测量同轴电流分流器的交流电压降来避免复杂而费时的交流直流电流传输测量。提出了使用商用交流电压表评估定制开发的同轴电流分流器的长期漂移,自热效应和负载的方法。通过仅校正分流器的长期漂移,可在20 Hz–30 kHz频率范围内以及100 mA至10 A的电流范围内获得低于55 $ muhbox {A / A} $的直接交流电流测量不确定度。