首页> 外文期刊>Inorganic materials >Application of gas chromatography mass spectrometry with preliminary dispersive liquid-liquid microextraction for the determination of low contents of rocket kerosene in water
【24h】

Application of gas chromatography mass spectrometry with preliminary dispersive liquid-liquid microextraction for the determination of low contents of rocket kerosene in water

机译:气相色谱质谱联用初步分散液-液微萃取在测定水中火箭煤油中低含量中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

A procedure for sensitive determination of rocket kerosene in water is described; it includes the dispersive liquid-liquid microextraction of analytes followed by their separation and determination by gas chromatography mass spectrometry in the mode of chromatogram registration against selected ions (m/z: 67, 81, 85, 95, 136, 137, 174, 183, and 193). The effect of the nature and volume of disperser and extraction solvents, salt additives, and the extraction duration on the efficiency of extraction of analytes is studied. The detectable concentration range is 0.005-0.05 mg/L. The detection limits (S/N = 3) of kerosene RG-1 and T-1 are 0.0015 and 0.0022 mg/L, respectively. The repeatability of the measurement results for the above range varies from 16 to 9% (n = 3); the intermediate precision varies from 20 to 12% (n = 5).
机译:描述了一种用于灵敏测定水中火箭煤油的程序。它包括分析物的分散液-液微萃取,分离和气相色谱质谱法以对选定离子的色谱配准方式进行测定(m / z:67、81、85、95、136、137、174、183和193)。研究了分散剂和萃取溶剂,盐添加剂的性质和体积以及萃取时间对分析物萃取效率的影响。可检测的浓度范围是0.005-0.05 mg / L。煤油RG-1和T-1的检出限(S / N = 3)分别为0.0015和0.0022 mg / L。在上述范围内,测量结果的重复性为16%至9%(n = 3);中间精度从20%到12%不等(n = 5)。