As a potential source of turn insulation failure, the steep-fronted voltage at the motor terminal generated by pulsewidth modulation drive switching or cable ringing is not uniformly distributed among the coils of the windings and among the turns of the coils. This paper presents a detailed electromagnetic analysis of the parameters of a transient model of coil and coil group which includes iron loss, skin, and proximity effects. The finite-difference method is applied to solve the model for the interturn and intercoil voltage distributions. The simulation is compared to a simplified lattice diagram analysis and to test results. A turn insulation surge-withstanding capability study is then presented with a flexible insulation test system that models the repetitive steep-fronted voltage stress and temperature stress.
机译:作为潜在的匝间绝缘故障的源,由脉冲宽度调制驱动开关或电缆振铃产生的电动机端子处的陡峭前沿电压未均匀地分布在绕组的线圈之间和线圈的匝之间。本文对线圈和线圈组瞬态模型的参数进行了详细的电磁分析,其中包括铁损,集肤和邻近效应。应用有限差分法求解匝间和线圈间电压分布模型。将模拟与简化的晶格图分析进行比较并测试结果。然后,通过灵活的绝缘测试系统对匝间绝缘承受浪涌的能力进行了研究,该系统对重复的陡峭前沿电压应力和温度应力进行建模。