Rotor cage asymmetries of induction machines cause disturbances of the air-gap flux pattern. These deviations affect torque and speed as well as stator terminal voltages and currents. The proposed fault detection technique senses the actual machine state with the help of real-time space-phasor models. The Vienna Monitoring Method compares online a voltage model output with a current model and observes the deviations in a rotor fixed reference frame. High accuracy and robustness allow the detection of a faulty rotor bar out of the switched voltage and current signals of an inverter-fed machine in an early state. The focus of this paper is the detection of a single rotor bar increase under transient speed conditions without the necessity of a clutched load. During an inverter-controlled acceleration, lasting only 200 ms, the Vienna Monitoring Method evaluates currents, voltages, and rotor position for the calculation of an indication quantity that allows for reliable detection. As only one acceleration task does not excite every rotor cage bar sufficiently, a set of acceleration and deceleration cycles has to be driven.
机译:感应电机的转子笼不对称会引起气隙通量模式的干扰。这些偏差会影响转矩和速度以及定子端子的电压和电流。所提出的故障检测技术借助实时空间相量模型检测实际的机器状态。维也纳监测方法在线比较电压模型输出和电流模型,并观察转子固定参考系中的偏差。高精度和鲁棒性允许在早期状态下从逆变器供电的机器的开关电压和电流信号中检测出故障的转子条。本文的重点是在瞬态转速条件下检测单个转子导条增加而无需离合器负载的情况。在仅持续200 ms的变频器控制的加速过程中,Vienna Monitoring Method评估电流,电压和转子位置,以计算指示量,从而实现可靠检测。由于只有一个加速任务不能充分激发每个转子笼杆,因此必须驱动一组加速和减速循环。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号