This paper assesses the suitability of the sandwiched-winding matrix HF power transformer for low-profile applications from the loss standpoint. Finite-element simulations and experiments suggest that the core loss can be adequately characterized by approximating the matrix transformer as a collection of identical uncoupled elements. Thus, a matrix transformer with a large number of elements may have higher core loss than a conventional (tall) transformer, and more core loss than winding loss. Eddy-current analysis reveals that the interconnects which parallel the elements incur a significant fraction of the winding loss. Thus, load distribution is recommended to eliminate the paralleling interconnects in matrix transformers.
机译:本文从损耗的角度评估了夹心式绕组矩阵高频电力变压器在低剖面应用中的适用性。有限元仿真和实验表明,通过将矩阵变压器近似为一组相同的未耦合元件,可以充分表征铁损。因此,具有大量元件的矩阵变压器可以具有比常规(高)变压器更高的铁损,并且可以具有比绕组损耗更高的铁损。涡流分析表明,与元件并联的互连会产生很大一部分绕组损耗。因此,建议分配负载以消除矩阵变压器中的并联互连。