This paper presents a fault detection and isolation (FDI) method for open-circuit faults of power semiconductor devices in a modular multilevel converter (MMC). The proposed FDI method is simple with only one sliding-mode observer (SMO) equation and requires no additional transducers. The method is based on an SMO for the circulating current in an MMC. An open-circuit fault of power semiconductor device is detected when the observed circulating current diverges from the measured one. A fault is located by employing an assumption-verification process. To improve the robustness of the proposed FDI method, a new technique based on the observer injection term is introduced to estimate the value of the uncertainties and disturbances; this estimated value can be used to compensate the uncertainties and disturbances. As a result, the proposed FDI scheme can detect and locate an open-circuit fault in a power semiconductor device while ignoring parameter uncertainties, measurement error, and other bounded disturbances. The FDI scheme has been implemented in a field-programmable gate array using fixed-point arithmetic and tested on a single-phase MMC prototype. Experimental results under different load conditions show that an open-circuit faulty power semiconductor device in an MMC can be detected and located in less than 50 ms.
机译:本文提出了一种用于模块化多电平转换器(MMC)中功率半导体器件开路故障的故障检测和隔离(FDI)方法。所提出的FDI方法非常简单,仅具有一个滑模观察器(SMO)方程,并且不需要其他传感器。该方法基于SMO,用于MMC中的循环电流。当观察到的循环电流与测量的电流不同时,就会检测到功率半导体器件的开路故障。通过采用假设验证过程来定位故障。为了提高所提出的FDI方法的鲁棒性,引入了一种基于观察者注入项的新技术来估计不确定性和扰动的值。该估计值可用于补偿不确定性和干扰。结果,所提出的FDI方案可以检测并定位功率半导体器件中的开路故障,而无需考虑参数不确定性,测量误差和其他有界干扰。 FDI方案已使用定点算法在现场可编程门阵列中实现,并在单相MMC原型上进行了测试。不同负载条件下的实验结果表明,MMC中的开路故障功率半导体器件可以在不到50 ms的时间内被检测到并定位。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号