首页> 外文期刊>IEEE Transactions on Power Electronics >Improving Planar Transformers for LLC Resonant Converters: Paired Layers Interleaving
【24h】

Improving Planar Transformers for LLC Resonant Converters: Paired Layers Interleaving

机译:用于 LLC 谐振转换器的平面变压器的改进:成对层交错

获取原文
获取原文并翻译 | 示例
           

摘要

With the increasing demand for flat displays, slim telecom/IT power supplies, and portable devices, the use of planar transformers (PTs) is becoming mandatory to achieve slim, compact converter designs. In particular, PTs present a significant opportunity to replace tall and bulky wire-wound transformers in industry standard LLC converters. However, the common-mode (CM) noise generated by PTs remains a significant obstacle to make LLCs effective. The CM noise issues are originated by large capacitances in overlapping primary and secondary layers of PTs, leading to serious electromagnetic interference issues. This paper develops a new winding method to overcome CM noise in LLC PTs. By minimizing noise, the proposed method prevents the use of bulky CM chokes, helping to keep a slim/flat form factor for LW converters with high-power density. As well, the proposed winding method maintains low ac resistance and leakage inductance, two desirable features in high-efficiency transformers. The paper explains the root cause of CM noise in LLC PTs and develops a comprehensive method that targets all sources of CM noise in the transformer and is applicable to any type of PTs. The proposed winding method successfully shields problematic turns with high dv/dt and overlaps the turns with the same dv/dt. As a result, circulating currents between primary and secondary (which are known as CM noise) are prevented, which leads to significant reduction of the converter's noise. Experimental results show that the proposed PT generates 11-20 dB mu V less CM noise than a traditional PT with the same parasitic capacitance, which is the result of using the proposed winding method.
机译:随着对平面显示器,超薄电信/ IT电源和便携式设备的需求不断增长,使用平面变压器(PT)成为实现超薄,紧凑型转换器设计的必由之路。尤其是,PT提供了重大的机会来替代行业标准LLC转换器中的高大体积的绕线变压器。但是,PT产生的共模(CM)噪声仍然是使LLC变得有效的重要障碍。 CM噪声问题是由PT重叠的初级和次级层中的大电容引起的,从而导致严重的电磁干扰问题。本文开发了一种新的绕线方法来克服LLC PT中的CM噪声。通过使噪声最小化,所提出的方法可以防止使用笨重的CM扼流圈,从而有助于为具有高功率密度的LW转换器保持纤薄/扁平的外形。同样,提出的绕组方法保持了低交流电阻和漏感,这是高效变压器中的两个理想特性。本文解释了LLC PT中CM噪声的根本原因,并开发了一种针对变压器中所有CM噪声源的综合方法,适用于任何类型的PT。所提出的绕组方法成功地屏蔽了具有高dv / dt的有问题的匝,并以相同的dv / dt重叠了匝。结果,防止了初级和次级之间的循环电流(称为CM噪声),从而显着降低了转换器的噪声。实验结果表明,所提出的PT产生的CM噪声比具有相同寄生电容的传统PT少11-20 dBμV的CM噪声,这是使用所提出的绕组方法的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号