首页> 外文期刊>IEEE Transactions on Circuits and Systems. I, Regular Papers >The use of linear models in A/D converter testing
【24h】

The use of linear models in A/D converter testing

机译:线性模型在A / D转换器测试中的使用

获取原文
获取原文并翻译 | 示例
           

摘要

This paper demonstrates how a linear modeling technique can be applied to three common methods for testing analog-to-digital converters (ADC's)-the servo-loop method, the tally-and-weight method, and the code density method-to improve their efficiency and accuracy. In order to compare the accuracy of the test procedures that incorporate the linear modeling technique with the corresponding procedures that do not, confidence intervals are derived for the integral and differential nonlinearity (INL and DNL) estimates obtained in both cases. Since the linear model may itself introduce some error in the estimates, the accuracy of the model must be determined in order to make the comparisons meaningful. This is accomplished by using a nested experimental design to determine how much of the variance in the transition levels is accounted for by the model
机译:本文演示了如何将线性建模技术应用于测试模数转换器(ADC)的三种常用方法-伺服环方法,计数和权重方法以及代码密度方法-来改进它们效率和准确性。为了比较结合了线性建模技术的测试过程的准确性与没有采用线性建模技术的测试过程的准确性,推导了在两种情况下获得的积分和微分非线性(INL和DNL)估计值的置信区间。由于线性模型本身可能会在估计中引入一些误差,因此必须确定模型的准确性才能使比较有意义。这是通过使用嵌套的实验设计来确定模型在过渡级别中占多少变化来实现的