The direct voltage sparkover characteristics of the rod-rod and the rod-plane electrode gaps systems are presented and compared. It is shown that for both arrangements the linearity is limited by the effects of atmospheric humidity for small (>0.25 metre) and large (<1 metre) electrode separations. The characteristics are discussed in terms of leader growth in the prebreakdown discharge; this is humidity dependent and is shown to be more prominent in the rod-rod gap. The precision and useful range of measurements in the two gaps are compared, particularly in relation to the recent approval of the rod-rod gap as a device for direct voltage measurement by the IEC.
机译:给出并比较了杆-杆和杆-平面电极间隙系统的直流电压火花放电特性。结果表明,对于两种布置,线性度均受较小(> 0.25米)和较大(<1米)电极间距的大气湿度的影响。讨论了这些特征,包括预分解排放中的领导者成长。这是取决于湿度的,并且在杆-杆间隙中表现得更为突出。比较了两个间隙中的精确度和有用的测量范围,特别是与IEC最近批准的杆-杆间隙作为直接电压测量的设备有关。