CMOS LNA for wireless biomedical telemetry

机译:用于无线生物医学遥测的CMOS LNA

获取原文
获取原文并翻译 | 示例
           

摘要

A low-noise amplifier (LNA) fabricated in a standard 0.35 (mu)m AMS CMOS process is described. The LNA is part of a telemetry system which is part of a R&D project for biomedical applications. The goal is to build a low-power 174-230 MHz RF transmitter-receiver suitable for measuring blood pressure on a patient body. The low noise amplifier is composed of transistors only, which allows full integration on a standard CMOS process. The LNA has been measured to have a noise figure of 2.6 dB and a 21.7 dB gain at 200 MHz. The input IP3 is -12 dBm.
机译:描述了以标准的0.35μmAMS CMOS工艺制造的低噪声放大器(LNA)。 LNA是遥测系统的一部分,该遥测系统是生物医学应用程序研发项目的一部分。目标是构建一种低功率174-230 MHz射频收发器,适合测量患者体内的血压。低噪声放大器仅由晶体管组成,因此可以完全集成在标准CMOS工艺中。经测量,LNA在200 MHz时的噪声系数为2.6 dB,增益为21.7 dB。输入IP3为-12 dBm。