首页> 外文期刊>Hydrological ProcHydrological Processesrnesses >Calibration of tipping-bucket flow meters and rain gauges to measure gross rainfall, throughfall, and stemflow applied to data from a Japanese temperate coniferous forest and a Cambodian tropical deciduous forest
【24h】

Calibration of tipping-bucket flow meters and rain gauges to measure gross rainfall, throughfall, and stemflow applied to data from a Japanese temperate coniferous forest and a Cambodian tropical deciduous forest

机译:用于测量日本温带针叶林和柬埔寨热带落叶林数据的自卸桶流量计和雨量计的标定,以测量总降雨量,贯通量和茎流量

获取原文
获取原文并翻译 | 示例
           

摘要

Tipping-bucket flow meter and rain gauge (TBFM/TBRG) are widely used for the measurement of gross rainfall (GR), throughfall (TF), and stemflow (SF) to evaluate the amount of interception loss (I). However, TBFM/TBRG cannot measure the inflow rate during tipping and underestimates the inflow rate. To correct this systematic bias, 33 total calibrations were conducted for five types of TBFM/TBRG in the laboratory. The tipping time increased with the bucket volume, and the underestimation during one tip was higher for TBFM/TBRG of larger capacity. With the use of the scaled actual inflow rate and the actual volume of a single tip from the measured static volume of a single tip when the inflow rate is zero, the common calibration curves were obtained as quadratic equations for each of the five types within an error range of ±3%. We measured GR and TF by using TBRG and TBFM with a resolution of 0.2 mm and measured SF by TBRG with a single-tip static volume of 15.7 cm3 in a Japanese temperate coniferous forest (TCF) and a Cambodian tropical deciduous forest (TDF). At both sites, the calibration curves needed to be applied to obtain GR, TF, and SF on an event scale with an underestimation degree of less than 3%. Without applying any calibrations, the higher rainfall intensities in TDF caused larger underestimations of GR, TF, and SF and larger overestimations of I compared with results for TCF. On an annual scale, the degree of overestimation of I relative to GR (ΔI/GR) was 1.2% in TCF and 3.5% in TDF, and ΔI/I was at least 10% at both sites. Copyright © 2012 John Wiley & Sons, Ltd.
机译:翻斗式流量计和雨量计(TBFM / TBRG)被广泛用于测量总降雨量(GR),穿透量(TF)和茎流(SF),以评估截留损失量(I)。但是,TBFM / TBRG无法测量倾卸过程中的流入速率,并且低估了流入速率。为了纠正这种系统性偏差,实验室对五种类型的TBFM / TBRG进行了33次总校准。翻斗时间随铲斗体积的增加而增加,而对于大容量的TBFM / TBRG,一次翻斗的低估率更高。通过使用缩放后的实际流入量和流入量为零时单个测得的单个吸头的静态体积的单个吸头的实际体积,可以得到常见的校准曲线,作为二次方程式,可以对三种类型中的每种吸头进行校准。误差范围为±3%。我们在日本温带针叶林(TCF)和柬埔寨热带落叶林(TDF)中,通过使用TBRG和TBFM以0.2 resolutionmm的分辨率测量了GR和TF,并通过TBRG以15.7 cm3的单尖端静态量测量了SF。在两个站点上,都需要应用校准曲线来获得事件标度上的GR,TF和SF,低估度低于3%。与TCF的结果相比,在不应用任何校准的情况下,TDF中较高的降雨强度导致对GR,TF和SF的低估较大,而对I的高估则较大。在年尺度上,TC中I相对于GR的高估程度(ΔI/ GR)为1.2%,TDF中为3.5%,两个站点的ΔI/ I至少为10%。版权所有©2012 John Wiley&Sons,Ltd.

著录项

  • 来源
  • 作者单位

    Department of Soil and Water Conservation Forestry and Forest Products Research Institute Ibaraki Japan;

    Department of Soil and Water Conservation Forestry and Forest Products Research Institute Ibaraki Japan;

    Kyushu Research Center Forestry and Forest Products Research Institute Kumamoto Japan;

    Department of Soil and Water Conservation Forestry and Forest Products Research Institute Ibaraki Japan;

    Department of Soil and Water Conservation Forestry and Forest Products Research Institute Ibaraki Japan;

    Kyushu Research Center Forestry and Forest Products Research Institute Kumamoto Japan;

    Hokkaido Research Center Forestry and Forest Products Research Institute Hokkaido Japan;

    Department of Forest Site Environment Forestry and Forest Products Research Institute Ibaraki Japan;

    Hokkaido Research Center Forestry and Forest Products Research Institute Hokkaido Japan;

    Department of Soil and Water Conservation Forestry and Forest Products Research Institute Ibaraki Japan;

    Forest–Wildlife Research and Development Institute Forestry Administration Phnom Penh Cambodia;

    Forest–Wildlife Research and Development Institute Forestry Administration Phnom Penh Cambodia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    tipping-bucket flow meter; rain gauge; underestimation; event scale; static volume of a single tip;