首页> 外文期刊>Geothermics >Groundwater Heat Pump (GWHP) system modeling and Thermal Affected Zone (TAZ) prediction reliability: Influence of temporal variations in flow discharge and injection temperature
【24h】

Groundwater Heat Pump (GWHP) system modeling and Thermal Affected Zone (TAZ) prediction reliability: Influence of temporal variations in flow discharge and injection temperature

机译:地下水热泵(GWHP)系统建模和热影响区(TAZ)预测可靠性:流量变化和注入温度随时间变化的影响

获取原文
获取原文并翻译 | 示例
           

摘要

A fundamental aspect in Groundwater Heat Pump (GWHP) plant design is the correct evaluation of the Thermal Affected Zone (TAZ) that develops around the injection well, which is important to avoid interference with existing groundwater applications and underground infrastructure. Numerical methods facilitate the identification of temperature anomalies, and software tools such as the FEFLOW program used in this study assist in these determinations. The actual flow rate and injection temperature are highly time-variable and follow changes in building energy requirements. In order to accurately predict the TAZ, it is necessary to consider this time variability. We calculated the TAZ using hourly discharge flow and temperature data, then recalculated the TAZ using average daily, monthly, and seasonal energetic equivalents. The four simulation results were compared with groundwater temperature data measured using a downgradient piezometer in order to assess the reliability of the simulations. The quality of the simulation was satisfactory when hourly, daily, or monthly flow rate and injection temperature data were used, whereas the seasonal averages were not suitable for reliably assessing TAZ development.
机译:地下水热泵(GWHP)厂设计的一个基本方面是对注入井周围发展的热影响区(TAZ)的正确评估,这对于避免干扰现有的地下水应用和地下基础设施非常重要。数值方法有助于识别温度异常,本研究中使用的软件工具(例如FEFLOW程序)有助于进行这些确定。实际流量和注入温度在很大程度上随时间变化,并随建筑能耗的变化而变化。为了准确预测TAZ,有必要考虑此时间可变性。我们使用每小时排放流量和温度数据计算了TAZ,然后使用平均每日,每月和季节性能量当量重新计算了TAZ。为了评估模拟的可靠性,将这四个模拟结果与使用降压测压仪测得的地下水温度数据进行了比较。当使用每小时,每天或每月的流速和注射温度数据时,仿真质量令人满意,而季节性平均值不适合可靠地评估TAZ的发展。

著录项

  • 来源
    《Geothermics》 |2014年第7期|103-112|共10页
  • 作者单位

    Department of Environment, Land and Infrastructure Engineering (DIATI), Politecnico di Torino, C.so Duca degli Abruzzi 24,10129 Torino, Italy;

    Department of Environment, Land and Infrastructure Engineering (DIATI), Politecnico di Torino, C.so Duca degli Abruzzi 24,10129 Torino, Italy;

    Department of Environment, Land and Infrastructure Engineering (DIATI), Politecnico di Torino, C.so Duca degli Abruzzi 24,10129 Torino, Italy;

    Department of Environment, Land and Infrastructure Engineering (DIATI), Politecnico di Torino, C.so Duca degli Abruzzi 24,10129 Torino, Italy;

    Department of Energy (DENERG), Politecnico di Torino, C.so Duca degli Abruzzi 24,10129 Torino, Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Groundwater Heat Pumps; Thermal Affected Zone, FEFLOW; Energy equivalent; Italy;