In view of the deep dewatering of landfill sludge (LS) that had been buried for more than ten years in Shanghai, Fenton's reagent combined with a vacuum preloading method was proposed. First, a vacuum filtration test was carried out to study the optimal amount of Fenton's reagent for LS. Then, four filter membranes with different pore sizes were used for a vacuum preloading model box test to study the influence of pore size on the consolidation behaviour of LS. Through particle analysis, SEM and MIP testing, the consolidation behaviour of sludge under different pore sizes was studied from the microscopic perspective. The results show the following: the optimal amount of Fenton's reagent for conditioning LS is Fe2+ 4%, H2O2 12%; the water content of LS with different pore sizes is reduced from 73% to 56%-63%; the unconfined compressive strength is increased from 10 kPa to above 80 kPa; and the volume reduction ratio is approximately 50%, among which the filter pore size of 180-mu m has the best performance. The micro-test results show that the pore size of the filter membrane has an important influence on LS's consolidation. The research results can provide significant references for the in-situ treatment of LS.
机译:鉴于填埋场污泥(LS)的深水脱水,在上海埋设十多年来,芬顿试剂与真空预加载方法相结合。首先,进行真空过滤试验,以研究LS的最佳量的FENTON试剂。然后,使用具有不同孔径尺寸的四个过滤膜用于真空预加载模型盒测试,以研究孔径对LS的固结行为的影响。通过粒子分析,SEM和MIP测试,从微观角度研究了不同孔径下污泥的整合行为。结果表明:用于调节LS的FENTON试剂的最佳金额为FE2 + 4%,H2O2 12%;具有不同孔径尺寸的LS的水含量从73%降至56%-63%;非束缚的抗压强度从10kPa增加到80kPa以上;并且体积减少率约为50%,其中滤光孔径为180-mu m具有最佳性能。微观测试结果表明,过滤膜的孔径对LS的固结有重要影响。研究结果可以为LS的原位处理提供显着的参考。

著录项

  • 来源
    《Geotextiles and Geomembranes》 |2021年第1期|109-121|共13页
  • 作者单位

    Shanghai Univ Dept Civil Engn 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Univ Dept Civil Engn 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Univ Dept Civil Engn 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Univ Dept Civil Engn 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Chengtou Wastewater Treatment Co Ltd Shanghai Peoples R China;

    Shanghai Univ Dept Civil Engn 99 Shangda Rd Shanghai 200444 Peoples R China;

    Shanghai Univ Dept Civil Engn 99 Shangda Rd Shanghai 200444 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Sludge's deep dewatering; Fenton's reagent; Filter pore size; Clogging; Consolidation behaviour;

    机译:污泥的深水;Fenton的试剂;过滤孔径;堵塞;整合行为;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号