首页> 外文期刊>Fusion Engineering and Design >RF design and tests on a broadband, high-power coaxial quadrature hybrid applicable to ITER ICRF transmission line system for load-resilient operations
【24h】

RF design and tests on a broadband, high-power coaxial quadrature hybrid applicable to ITER ICRF transmission line system for load-resilient operations

机译:适用于ITER ICRF传输线系统的宽带,高功率同轴正交混合电路的RF设计和测试,可实现负载弹性操作

获取原文
获取原文并翻译 | 示例
           

摘要

RF design and network analyzer tests of broadband, amplitude-balanced coaxial hybrid junctions are presented. We have designed two 3 dB hybrid splitters with 9 and 12 in. coaxial transmission lines applicable to ITER ICRF for load-resilient operations using ANSYS HFSS. Amplitude-balanced broadband responses were obtained with the combination of impedance reductions of longitudinal and transverse branches in unequal proportion, length change of 50 Omega lines and diameter change of high impedance lines connected transversely to the T-section of the hybrid splitter, respectively. We have fabricated and RF tested the 9 in. coaxial hybrid coupler. We obtained an excellent coupling flatness of -3.2 +/- 0.2 dB, phase difference of 4 degrees and return loss of 16 dB in 40-55 MHz. The measured data of 9 in. hybrid splitter is highly consistent with HFSS simulations. We found that the proposed 3 dB hybrid splitter can be tunable with amplitude-balanced, broadband response by changing dielectric insulators to keep the inner and outer conductors of coaxial line apart. The proposed 3 dB hybrid splitter can be utilized for load-resilient operations in a wide range of antenna load variations due to mode transitions or edge localized modes (ELMs) in fusion plasmas. (C) 2015 Elsevier B.V. All rights reserved.
机译:提出了宽带,振幅平衡同轴混合结的射频设计和网络分析仪测试。我们设计了两个3 dB混合分配器,分别具有9和12英寸同轴传输线,适用于ITER ICRF,可使用ANSYS HFSS进行负载弹性操作。通过分别以不等比例的纵向和横向分支的阻抗减小,50Ω的长度变化和横向连接到混合式分离器T形截面的高阻抗线的直径变化的组合,获得了振幅平衡的宽带响应。我们已经制造并通过射频测试9英寸同轴混合耦合器。在40-55 MHz中,我们获得了-3.2 +/- 0.2 dB的出色耦合平坦度,4度的相位差和16 dB的回波损耗。 9英寸混合分流器的测量数据与HFSS仿真高度一致。我们发现,建议的3 dB混合分路器可以通过改变介电绝缘体以保持同轴线的内外导体分开来实现振幅平衡,宽带响应的可调。由于融合等离子体中的模式转换或边缘局部模式(ELM),建议的3 dB混合分配器可用于各种天线负载变化中的负载弹性操作。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号