首页> 外文期刊>Fusion Engineering and Design >Study on normal operation and failure of pressure control for CN HCCB TBS primary coolant system
【24h】

Study on normal operation and failure of pressure control for CN HCCB TBS primary coolant system

机译:CN HCCB TBS主冷却液系统正常运行和压力控制失效的研究

获取原文
获取原文并翻译 | 示例
           

摘要

Based on the design requirement of the test blanket module (TBM) and the design parameters of the helium coolant system (HCS) primary loop, the preliminary design of the pressure control system (PCS), including control logic and main parameters, has been completed. The one-dimensional thermal hydraulic model has been created based on the PCS. According to the operation scenario of international thermal nuclear experimental reactor (ITER), several operating cases, including normal operating cases and PCS failure cases, have been studied. The results show that the PCS design is feasible and the inlet pressure of the TBM can be controlled to remain around 8 MPa. The PCS failures impact the pressure of the HCS as well as the inlet pressure of the TBM severely, while the impacts on the temperature of the TBM are not significant.
机译:根据测试毯模块(TBM)的设计要求和氦冷却剂系统(HCS)主回路的设计参数,已经完成了压力控制系统(PCS)的初步设计,包括控制逻辑和主要参数。 。基于PCS已创建一维热力水力模型。根据国际热核实验堆(ITER)的运行情况,研究了几种运行案例,包括正常运行案例和PCS失效案例。结果表明,PCS设计是可行的,TBM的入口压力可以控制在8 MPa左右。 PCS故障严重影响HCS的压力以及TBM的入口压力,而对TBM温度的影响并不明显。