首页> 外文期刊>Fuel >High temperature corrosion of boiler waterwalls induced by chlorides and bromides - Part 2: Lab-scale corrosion tests and thermodynamic equilibrium modeling of ash and gaseous species
【24h】

High temperature corrosion of boiler waterwalls induced by chlorides and bromides - Part 2: Lab-scale corrosion tests and thermodynamic equilibrium modeling of ash and gaseous species

机译:氯化物和溴化物引起的锅炉水冷壁的高温腐蚀第2部分:实验室规模的灰分和气态物质腐蚀试验和热力学平衡模型

获取原文
获取原文并翻译 | 示例
           

摘要

In Part 1 of the work a measurement campaign was carried out to determine the occurrence of corrosive ash components in a bubbling fluidized bed (BFB) boiler combusting solid recovered fuel (SRF). It was found out that the main ash-forming elements that had been vaporized and subsequently condensed from the gas phase were Na, K, S and Cl together with minor amounts of Zn, Pb, Cu, and Br. Both, Cl and Br were found in the corrosion front of the waterwalls prior to the measurement campaign. In this work, the forms of ash forming elements in the combustion gases and in the waterwall deposits of the examined boiler were predicted by means of thermodynamic equilibrium modeling. Laboratory tests were also carried out to estimate the degree of corrosion of boiler steels under bromine containing deposits. A mixture of ZnBr_2 and K_2SO_4 was selected for high temperature lab-scale corrosion testing since Zn, Br and K as well as sulfates were present in the deposit and it was possible to compare these results to previously published results with ZnCl_2-K_2SO_4 mixtures. The comparison showed that more severe material degradation was caused by the ZnBr_2 containing salt than by the corresponding chloride and corrosion was significant already at 400 ℃.
机译:在工作的第1部分中,进行了一项测量活动,以确定在燃烧固体回收燃料(SRF)的鼓泡流化床(BFB)锅炉中腐蚀性灰分的出现。发现已经汽化并随后从气相冷凝的主要成灰元素是Na,K,S和Cl以及少量的Zn,Pb,Cu和Br。在进行测量之前,在水冷壁的腐蚀前沿发现了Cl和Br。在这项工作中,通过热力学平衡模型预测了所检查锅炉的燃烧气体和水冷壁沉积物中灰分形成元素的形式。还进行了实验室测试,以评估锅炉钢在含溴沉积物中的腐蚀程度。由于沉积物中存在Zn,Br和K以及硫酸盐,因此选择ZnBr_2和K_2SO_4的混合物进行高温实验室规模的腐蚀测试,并且可以将这些结果与ZnCl_2-K_2SO_4混合物进行比较。比较表明,含ZnBr_2的盐比相应的氯化物引起的材料降解更为严重,并且在400℃时腐蚀已经很明显。

著录项

  • 来源
    《Fuel》 |2012年第2012期|p.240-250|共11页
  • 作者单位

    Abo Akademi Process Chemistry Centre, Piispankatu 8, FIN-20500 Turku, Finland;

    VTT, Koivurannantie 1, FIN-40101 Jyvaskyla, Finland;

    Abo Akademi Process Chemistry Centre, Piispankatu 8, FIN-20500 Turku, Finland;

    Stora Enso Newsprint & Book Paper, Anjalankoski Mills, FIN-46900 Anjalankoski, Finland;

    Metso Power, Lentokentankatu 11, FIN-33900 Tampere, Finland;

    Abo Akademi Process Chemistry Centre, Piispankatu 8, FIN-20500 Turku, Finland;

    Abo Akademi Process Chemistry Centre, Piispankatu 8, FIN-20500 Turku, Finland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    bromine; chlorine; waterwall; corrosion; solid recovered fuel;

    机译:溴;氯;水冷壁腐蚀;固体回收燃料;