首页> 外文期刊>Experimental Heat Transfer >EXPERIMENTAL INVESTIGATION OF CONTACT HEAT TRANSFER AT HIGH TEMPERATURE BASED ON STEADY-STATE HEAT FLUX METHOD
【24h】

EXPERIMENTAL INVESTIGATION OF CONTACT HEAT TRANSFER AT HIGH TEMPERATURE BASED ON STEADY-STATE HEAT FLUX METHOD

机译:基于稳态热通量法的高温接触换热实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Based on the steady-state heat flux method, the effects of interfacial temperature (320℃-550℃) and contact pressure (2.96-15.68 MPa) on the contact heat transfer were investigated by a new experimental apparatus and method. To accurately measure the interfacial temperature drop, six thin specimens, alternately overlapped together between two test specimens, were applied. The experimental results show that thermal contact conductance increases with the increase of interfacial temperature and contact pressure generally. In addition, the variation of thermal contact conductance for different contact pressure is more obvious at higher temperature. The basic tendency of the power law correlation between thermal contact conductance and contact pressure agrees well with that of available theoretical models.
机译:基于稳态热通量方法,采用新的实验装置和方法研究了界面温度(320℃-550℃)和接触压力(2.96-15.68 MPa)对接触传热的影响。为了准确测量界面温度下降,应用了六个薄样本,两个样本之间交替重叠。实验结果表明,热接触电导率一般随着界面温度和接触压力的增加而增加。另外,在较高的温度下,不同接触压力下热接触电导的变化更为明显。热接触电导和接触压力之间的幂律相关性的基本趋势与可用的理论模型相吻合。