...
首页> 外文期刊>European Spine Journal >Assessment of lumbosacral kyphosis in spondylolisthesis: a computer-assisted reliability study of six measurement techniques
【24h】

Assessment of lumbosacral kyphosis in spondylolisthesis: a computer-assisted reliability study of six measurement techniques

机译:腰ac椎腰后凸畸形的评估:六种测量技术的计算机辅助可靠性研究

获取原文
获取原文并翻译 | 示例
           

摘要

Although recognized as an important aspect in the management of spondylolisthesis, there is no consensus on the most reliable and optimal measure of lumbosacral kyphosis (LSK). Using a custom computer software, four raters evaluated 60 standing lateral radiographs of the lumbosacral spine during two sessions at a 1-week interval. The sample size consisted of 20 normal, 20 low and 20 high grade spondylolisthetic subjects. Six parameters were included for analysis: Boxall’s slip angle, Dubousset’s lumbosacral angle (LSA), the Spinal Deformity Study Group’s (SDSG) LSA, dysplastic SDSG LSA, sagittal rotation (SR), kyphotic Cobb angle (k-Cobb). Intra- and inter-rater reliability for all parameters was assessed using intra-class correlation coefficients (ICC). Correlations between parameters and slip percentage were evaluated with Pearson coefficients. The intra-rater ICC’s for all the parameters ranged between 0.81 and 0.97 and the inter-rater ICC’s were between 0.74 and 0.98. All parameters except sagittal rotation showed a medium to large correlation with slip percentage. Dubousset’s LSA and the k-Cobb showed the largest correlations (r = −0.78 and r = −0.50, respectively). SR was associated with the weakest correlation (r = −0.10). All other parameters had medium correlations with percent slip (r = 0.31–0.43). All measurement techniques provided excellent inter- and intra-rater reliability. Dubousset’s LSA showed the strongest correlation with slip grade. This parameter can be used in the clinical setting with PACS software capabilities to assess LSK. A computer-assisted technique is recommended in order to increase the reliability of the measurement of LSK in spondylolisthesis.
机译:尽管被认为是治疗腰椎滑脱的重要方面,但对于腰s椎后凸畸形(LSK)的最可靠和最佳测量方法尚无共识。使用定制的计算机软件,四个评估者在两个疗程中以1周的间隔评估了腰s部脊柱的60张站立侧位X光片。样本量包括20名正常,20名低和20名高级别脊椎滑脱受试者。分析中包括六个参数:Boxall的滑移角,Dubousset的腰s角(LSA),脊柱畸形研究组(SDSG)LSA,发育不良的SDSG LSA,矢状旋转(SR),后凸科布角(k-Cobb)。使用类内相关系数(ICC)评估所有参数的评分者内部和评分者之间的可靠性。使用皮尔森系数评估参数和滑移百分比之间的相关性。所有参数的评估者内部ICC介于0.81和0.97之间,评估者间ICC介于0.74和0.98之间。除矢状旋转外,所有参数均显示与滑移百分比具有中等到较大的相关性。 Dubousset的LSA和k-Cobb具有最大的相关性(分别为r = -0.78和r = -0.50)。 SR与最弱的相关性相关(r = -0.10)。所有其他参数与滑动百分率具有中等相关性(r = 0.31–0.43)。所有测量技术均提供出色的评估者内部和评估者可靠性。 Dubousset的LSA与滑坡等级之间的相关性最强。此参数可在具有PACS软件功能的临床设置中用于评估LSK。推荐使用计算机辅助技术,以增加脊椎滑脱中LSK测量的可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号