摘要

Frequency-domain photothermal radiometry (FD-PTR or PTR) has been used to detect mechanical holes and demineralized enamel in the interproximal contact area of extracted human teeth. Thirty four teeth were used in a series of experiments. Preliminary tests to detect mechanical holes created by dental burs and 37% phosphoric acid etching for 20 s on the interproximal contact points showed distinct differences in the signal. Interproximal contact areas were demineralized by using a partially saturated acidic buffer system. Each sample pair was examined with PTR before and after micro-machining or treating at sequential treatment periods spanning 6 hours to 30 days. Dental bitewing radio graphs showed no sign of demineralized lesion even for samples treated for 30 days. μ-CT, TMR and SEM analyses were performed. Although μ-CT and TMR measured mineral losses and lesion depths, only SEM surface images showed visible signs of treatment because of the minimal extent of the demineralization. However, the PTR amplitude increased by more than 300% after 80 hours of treatment. Therefore, PTR has been shown to have sufficient contrast for the detection of very early interproximal demineralized lesions. The technique further exhibited excellent signal reproducibility and consistent signal changes in the presence of interproximal demineralized lesions, attributes which render PTR a reliable probe to detect early interproximal demineralization lesions. Modulated luminescence was also measured simultaneously, but it showed a lower ability to detect these interproximal demineralized lesions than PTR.
机译:频域光热辐射法(FD-PTR或PTR)已用于检测拔出的人类牙齿近端接触区域中的机械孔和脱矿质牙釉质。在一系列实验中使用了34颗牙齿。初步测试检测了牙钻和37%磷酸蚀刻在牙间接触点上20 s所产生的机械孔,结果显示信号存在明显差异。通过使用部分饱和的酸性缓冲液系统使近邻接触区域脱矿质。在微加工或在6小时至30天的连续治疗周期之前和之后,对每个样品对进行PTR检查。牙科咬合放射图显示,即使治疗30天的样品也未见脱矿质病变的迹象。进行了μ-CT,TMR和SEM分析。尽管μ-CT和TMR测量了矿物质损失和病灶深度,但由于去矿质的程度最小,只有SEM表面图像显示出明显的治疗迹象。但是,治疗80小时后,PTR幅度增加了300%以上。因此,已显示PTR具有足够的对比度,可用于检测非常早期的近端间脱矿质病变。该技术在近端脱矿质病变的存在下还表现出了出色的信号再现性和一致的信号变化,这些属性使PTR成为检测早期近端脱矿质病变的可靠探针。还同时测量了调制的发光,但是它显示出比PTR更低的检测这些近端间脱矿质病变的能力。

著录项

  • 来源
    《The European Physical Journal Special Topics》 |2008年第1期|467-469|共3页
  • 作者单位

    Center for Advanced Diffusion Wave Technologies Dept. of Mechanical and Industrial Engineering University of Toronto Toronto Ontario Canada;

    Center for Advanced Diffusion Wave Technologies Dept. of Mechanical and Industrial Engineering University of Toronto Toronto Ontario Canada;

    Center for Advanced Diffusion Wave Technologies Dept. of Mechanical and Industrial Engineering University of Toronto Toronto Ontario Canada;

    Four Cell Consulting Toronto Ontario Canada;

    Cariology Unit Department of Community Dentistry University of Texas Health Science Center at San Antonio San Antonio Texas USA;

    Faculty of Dentistry University of Toronto Toronto Ontario Canada;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号