Assessing the accuracy of tympanometric evaluation of external auditory canal volume: a scientific study using an ear canal model

机译:评估鼓室外耳道容积的鼓室测量准确性:使用耳道模型的科学研究

获取原文
获取原文并翻译 | 示例
           

摘要

Tympanometric evaluation is routinely used as part of the complete otological examination. During tympanometric examination, evaluation of middle ear pressure and ear canal volume is undertaken. Little is reported in relation to the accuracy and precision tympanometry evaluates external ear canal volume. This study examines the capability of the tympanometer to accurately evaluate external auditory canal volume in both simple and partially obstructed ear canal models and assesses its capability to be used in studies examining the effectiveness of cerumolytics. An ear canal model was designed using simple laboratory equipment, including a 5 ml calibrated clinical syringe (Becton Dickinson, Spain). The ear canal model was attached to the sensing probe of a Kamplex tympanometer (Interacoustics, Denmark). Three basic trials were undertaken: evaluation of the tympanometer in simple canal volume measurement, evaluation of the tympanometer in assessing canal volume with partial canal occlusion at different positions within the model, and evaluation of the tympanometer in assessing canal volume with varying degrees of canal occlusion. 1,290 individual test scenarios were completed over the three arms of the study. At volumes of 1.4 cm3 or below, a perfect relationship was noted between the actual and tympanometric volumes in the simple model (Spearman’s ρ = 1) with weakening degrees of agreement with increasing volume of the canal. Bland–Altman plotting confirmed the accuracy of this agreement. In the wax substitute models, tympanometry was observed to have a close relationship (Spearman’s ρ > 0.99) with the actual volume present with worsening error above a volume of 1.4 cm3. Bland–Altman plotting and precision calculations provided evidence of accuracy. Size and position of the wax substitute had no statistical effect on results [Wilcoxon rank-sum test (WRST) p > 0.99], nor did degree of partial obstruction (WRST p > 0.99). The Kamplex tympanometer accurately and precisely assesses ear canal volume in the scientific model in both simple and partially occluded wax substitute scenarios up to a volume of 1.4 cm3. These findings suggest that the Kamplex tympanometer could be used as an effective objective tool in evaluating the efficacy of topical cerumolytics in both laboratory and human models.
机译:鼓室评估通常用作完整的耳科检查的一部分。鼓室检查期间,对中耳压力和耳道容量进行评估。关于准确性和精确性的鼓室测压仪评估外耳道容积的报道很少。这项研究检查了鼓室压力计在简单和部分阻塞的耳道模型中准确评估外耳道容积的能力,并评估了其用于检查溶肠剂有效性的研究中的能力。使用简单的实验室设备(包括5 ml校准的临床注射器(西班牙Becton Dickinson))设计了耳道模型。将耳道模型连接到Kamplex鼓室计(丹麦Interacoustics)的传感探头上。进行了三个基本试验:在简单的运河容积测量中对鼓室压力的评估,在模型内不同位置处部分运河闭塞的情况下对鼓室容积的评估,在不同程度的运河阻塞的情况下对鼓室容积进行评估的鼓室压力的评估。在研究的三个方面完成了1,290个单独的测试场景。在1.4 cm 3 或以下的体积中,在简单模型(Spearmanρ= 1)中,实际体积和鼓室体积之间存在完美的关系,随着运河体积的增加,一致性减弱。 Bland–Altman绘图证实了该协议的准确性。在蜡替代模型中,观察到鼓室压与实际体积存在密切关系(Spearmanρ> 0.99),并且在1.4 cm 3 的体积上误差有所恶化。 Bland–Altman绘图和精度计算提供了准确性的证据。蜡替代物的大小和位置对结果无统计学影响[Wilcoxon秩和检验(WRST)p> 0.99],部分阻塞程度也无统计学意义(WRST p> 0.99)。在简单和部分阻塞的蜡替代方案中,Kamplex鼓室鼓膜仪可精确准确地评估耳道的体积,最大体积为1.4 cm 3 。这些发现表明,Kamplex鼓室测压计可以用作在实验室模型和人体模型中评估局部溶栓剂疗效的有效客观工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号