摘要

Developing a technique to track the release of phosphorus (P) and iron (Fe) simultaneously in sediments would be very useful in deepening our understanding of the internal loading process of P coupled with Fe cycling in aquatic systems. In this study, a new technique was established to measure simultaneously the dissolved reactive P (DRP) and dissolved Fe primarily released from sediment solids based on the diffusive gradients in thin films (DGT) theory. A mixed binding gel (ZrO-Chelex gel) used for assembling DGT was developed for simultaneous uptake of DRP and dissolved Fe(Ⅱ) using amorphous zirconium hydroxide (Zr-oxide) and Chelex-100 resin as binding agents. Simultaneous measurements of DRP and dissolved Fe(Ⅱ) with the ZrO-Chelex DGT were validated in solution and were independent of solution pH and ionic strength in normal environments. The capacities of the ZrO-Chelex DGT for measurements of DRP and dissolved Fe(Ⅱ) were 90 μg P cm~(-2) and 75 μg Fe cm~(-2), with the latter being greater than that (45 μg Fe cm~(-2)) observed with the Chelex-100 resin DGT commonly used in DGT measurements of metals. Microcosm experiments further confirmed the feasibility of the ZrO-Chelex DGT for simultaneous measurement of P and Fe in sediments, with a higher concentration of Fe being measured due to this method's higher capacity compared with the Chelex-100 resin DGT.
机译:开发一种技术来同时跟踪沉积物中磷(P)和铁(Fe)的释放对于加深我们对磷在水生系统中的内部加载过程以及铁循环的理解将非常有用。在这项研究中,建立了一种新技术,可根据薄膜中的扩散梯度(DGT)理论同时测量沉积物固体中主要释放的溶解性反应性P(DRP)和溶解性Fe。开发了用于组装DGT的混合结合凝胶(ZrO-Chelex凝胶),以非晶态氢氧化锆(Zr-氧化物)和Chelex-100树脂为结合剂,同时吸收DRP和溶解的Fe(Ⅱ)。 ZrO-Chelex DGT可同时测定DRP和溶解的Fe(Ⅱ),在正常环境下与溶液的pH值和离子强度无关。 ZrO-Chelex DGT的DRP和溶解的Fe(Ⅱ)的测量容量为90μgP cm〜(-2)和75μgFe cm〜(-2),后者大于(45μgFe用常用于金属DGT测量的Chelex-100树脂DGT观察到cm〜(-2))。缩影实验进一步证实了ZrO-Chelex DGT用于同时测量沉积物中P和Fe的可行性,由于与Chelex-100树脂DGT相比,该方法具有更高的容量,因此可以测量更高的Fe浓度。

著录项

  • 来源
    《Environmental Science & Technology》 |2013年第18期|10477-10484|共8页
  • 作者单位

    State Key Laboratory of Lake Science and Environment, Nanjing Institute of Geography and Limnology, Chinese Academy of Sciences, Nanjing 210008, China;

    College of Environmental Science and Engineering, Hohai University, Nanjing 210098, China;

    State Key Laboratory of Lake Science and Environment, Nanjing Institute of Geography and Limnology, Chinese Academy of Sciences, Nanjing 210008, China;

    College of Environmental Science and Engineering, Hohai University, Nanjing 210098, China;

    State Key Laboratory of Lake Science and Environment, Nanjing Institute of Geography and Limnology, Chinese Academy of Sciences, Nanjing 210008, China;

    GIS Centre, Ryan Institute and School of Geography and Archaeology, National University of Ireland, Galway, Ireland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号