The efficiency of the proposed strengthening method using externally applied post-tension rods in reinforced concrete external beam-column joints, which do not comply with any code requirements, is investigated. Five full-scale specimens were tested in the laboratory. They have specific deficiencies resulting from the lack of shear reinforcement in the joint and poor material properties including low strength concrete and the presence of plain round reinforcement bars. While all specimens were built with column and in plane beam, one of the tested specimens consists of a transverse beam to demonstrate the applicability of the presented retrofit technique. All specimens were subjected to a cyclic quasi-static loading up to 8% drift ratio to observe different levels of structural damage. Two post-tension rods, which were mounted diagonally at each side of the joint, are utilized as a local retrofit technique. The reference specimen displayed a brittle behavior with the concentration of shear cracks mostly in the joint while the rest of the RC components were almost in their elastic range. The ultimate lateral load capacity was increased considerably for all retrofitted specimens. However, a brittle type of failure mechanism was observed such as a joint shear failure or beam-joint failure in the three retrofitted specimens. A relatively ductile response was observed in the specimen with transverse beam, although the axial force in the post-tension rods was the same with the specimens without transverse beam. After testing all specimens, it is found that the lateral force capacities of the beam-column assemblies can be improved up to code requirements by the proposed retrofitting method. (C) 2015 Elsevier Ltd. All rights reserved.
机译:研究了在钢筋混凝土外部梁柱节点中使用外部施加的后拉力杆的建议加固方法的效率,该方法不符合任何规范要求。在实验室测试了五个全尺寸标本。它们具有特定的缺陷,这是由于接头处缺乏抗剪钢筋以及材料性能差(包括低强度混凝土和存在普通的圆形钢筋)造成的。当所有标本都用柱状梁和平面梁建造时,其中一个测试标本由横梁组成,以证明所提出的改造技术的适用性。所有标本都经受了高达8%的漂移比的周期性准静态载荷,以观察不同程度的结构损伤。将两个对角线安装在对角线的每一侧,作为局部改造技术。参考试样表现出脆性行为,剪切裂纹集中在接头处,而其余RC构件几乎处于其弹性范围内。所有翻新标本的极限侧向承载能力都大大提高。但是,在三个改型后的样品中观察到了脆性破坏机制,例如接头剪切破坏或梁-节点破坏。在带有横梁的试样中观察到了相对延性的响应,尽管后拉力杆中的轴向力与没有横梁的试样相同。对所有样品进行测试后,发现通过提出的改进方法,可以提高梁柱组件的侧向力能力,使其达到规范要求。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号