The in -plane seismic behavior was investigated for five single -story reinforced masonry shear walls (RMSWs) (four prefabricated and one cast -in -place) subjected to an axial compressive load and reverse lateral excitation. An innovative vertical joint connection method for the prefabricated RMSWs was developed. The variables under study were the level of axial compressive stress, horizontal reinforcement ratio, and construction method. The experimental results showed that all walls had a similar failure mode with diagonal cracking. However, the crack distribution depended strongly on the construction method. The bearing capacity of the walls increased with the applied axial compressive stress and amount of horizontal reinforcement. The prefabricated walls showed better post -cracking performance than the cast -in -place wall. The wall secant stiffness decreased rapidly to approximately 60% of the initial stiffness when the first major diagonal crack occurred. The idealized equivalent elastic -plastic system indicated that the prefabricated RMSWs had greater displacement ductility of 2.6 -4.7 than the cast -in -place RMSW. The equivalent viscous damping for the walls was 0.10 -0.20 at 0.32% drift, which indicates that RMSW buildings can be expected to provide a high level of damping to reduce the
机译:对五个单级增强砌体剪力墙(RMSW)(四个预制的和一个铸件 - 挡板)进行了调查了普通地震行为,经受轴向压缩载荷和反向横向激发。开发了一种用于预制RMSW的垂直联合连接方法。研究中的变量是轴向压缩应力,水平加强率和施工方法的水平。实验结果表明,所有墙壁都有类似的失效模式,具有对角线开裂。然而,裂缝分布依赖于施工方法。墙壁的承载力随着施加的轴向压缩应力和水平加强量的增加而增加。预制的墙壁显示出比Cast-Inplace墙壁更好的后克隆性能。当第一主要对角线裂纹发生时,壁分刚度迅速降低至初始刚度的大约60%。理想化的等效弹性 - 塑料系统表明预制的RMSWS比Cast-Inplace RMSW更大的位移延性为2.6 -4.7。墙壁的等效粘性阻尼为0.10-0.20,漂移在0.32%,这表明可以预期RMSW建筑物提供高水平的阻尼以减少

著录项

  • 来源
    《Engineering Structures》 |2020年第15期|110958.1-110958.13|共13页
  • 作者单位

    Harbin Inst Technol Sch Civil Engn Room 521 Haihe Rd 202 Harbin 150090 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Civil Engn Room 521 Haihe Rd 202 Harbin 150090 Heilongjiang Peoples R China|Harbin Inst Technol Key Lab Struct Dynam Behav & Control Minist Educ Harbin 150090 Peoples R China|Harbin Inst Technol Key Lab Smart Prevent & Mitigat Civil Engn Disast Minist Ind & Informat Technol Harbin 150090 Peoples R China;

    Harbin Inst Technol Sch Civil Engn Room 521 Haihe Rd 202 Harbin 150090 Heilongjiang Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Prefabricated reinforced masonry shear wall; Concrete masonry; Cyclic loading; Shear failure; Vertical joint; Seismic performance;

    机译:预制增强砌体剪力墙;混凝土砌体;循环载荷;剪切失效;垂直关节;地震性能;