首页> 外文期刊>Energy >Performance of a showcase refrigeration system with multi-evaporator during on-off cycling and hot-gas bypass defrost
【24h】

Performance of a showcase refrigeration system with multi-evaporator during on-off cycling and hot-gas bypass defrost

机译:具有多蒸发器的陈列柜制冷系统在开关循环和热气旁路除霜期间的性能

获取原文
获取原文并翻译 | 示例
           

摘要

During the defrosting process, the temperature in the cabinet of a showcase becomes higher than the set point. This phenomenon is undesirable for foods or products stored. It is essential to develop an efficient defrosting method to prevent large temperature fluctuations. In the present study, the performance of the showcase refrigeration system with three evaporators was measured during on-off cycling and hot-gas bypass defrost. Based on the test results, the effects of off-period in the on-off cycling and EEV opening in the hot-gas bypass defrosting cycle on the performance of showcase system were analyzed. In addition, the operating characteristics of the hot-gas bypass defrosting cycle were compared with those of the on-off cycling. The hot-gas bypass defrosting method showed higher refrigerating capacity and less temperature fluctuations than the on-off cycling under frosting/defrosting conditions even though it required more compressor power.
机译:除霜过程中,橱柜内的温度会高于设定值。这种现象对于所存储的食品或产品是不希望的。开发有效的除霜方法以防止较大的温度波动至关重要。在本研究中,在开关循环和热气旁路除霜过程中测量了具有三个蒸发器的陈列柜制冷系统的性能。根据测试结果,分析了开-关循环中的关闭时间和热气旁路除霜循环中的EEV开度对陈列柜系统性能的影响。另外,将热气旁路除霜循环的操作特性与开关循环的操作特性进行了比较。尽管需要更多的压缩机功率,但热气旁通除霜方法比起霜/除霜条件下的开关循环具有更高的制冷能力和较小的温度波动。