首页> 外文期刊>IEEE Transactions on Energy Conversion >An Enhanced Power Sharing Scheme for Voltage Unbalance and Harmonics Compensation in an Islanded AC Microgrid
【24h】

An Enhanced Power Sharing Scheme for Voltage Unbalance and Harmonics Compensation in an Islanded AC Microgrid

机译:孤岛式交流微电网中用于电压不平衡和谐波补偿的增强型功率共享方案

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, an enhanced hierarchical control structure with multiple current loop damping schemes for voltage unbalance and harmonics compensation (UHC) in ac islanded microgrid is proposed to address unequal power sharing problems. The distributed generation (DG) is properly controlled to autonomously compensate voltage unbalance and harmonics while sharing the compensation effort for the real power, reactive power, and unbalance and harmonic powers. The proposed control system of the microgrid mainly consists of the positive sequence real and reactive power droop controllers, voltage and current controllers, the selective virtual impedance loop, the unbalance and harmonics compensators, the secondary control for voltage amplitude and frequency restoration, and the auxiliary control to achieve a high-voltage quality at the point of common coupling. By using the proposed unbalance and harmonics compensation, the auxiliary control, and the virtual positiveegative-sequence impedance loops at fundamental frequency, and the virtual variable harmonic impedance loop at harmonic frequencies, an accurate power sharing is achieved. Moreover, the low bandwidth communication (LBC) technique is adopted to send the compensation command of the secondary control and auxiliary control from the microgrid control center to the local controllers of DG unit. Finally, the hardware-in-the-loop results using dSPACE 1006 platform are presented to demonstrate the effectiveness of the proposed approach.
机译:本文针对交流孤岛电网中的电压不平衡和谐波补偿(UHC),提出了一种具有多重电流环路阻尼方案的增强型分级控制结构,以解决不平等的功率分配问题。分布式发电(DG)受到适当控制,以自主补偿电压不平衡和谐波,同时分担有功功率,无功功率以及不平衡和谐波功率的补偿工作。拟议的微电网控制系统主要由正序有功和无功功率下降控制器,电压和电流控制器,选择性虚拟阻抗环路,不平衡和谐波补偿器,电压幅度和频率恢复的次级控制以及辅助系统组成。控制以在公共耦合点实现高压质量。通过使用拟议的不平衡和谐波补偿,辅助控制以及基频处的虚拟正/负序阻抗环路和谐波频率处的虚拟可变谐波阻抗环路,可以实现精确的功率共享。此外,采用低带宽通信(LBC)技术将次级控制和辅助控制的补偿命令从微电网控制中心发送到DG单元的本地控制器。最后,提出了使用dSPACE 1006平台的硬件在环结果,以证明所提出方法的有效性。

著录项

  • 来源
    《IEEE Transactions on Energy Conversion》 |2016年第3期|1037-1050|共14页
  • 作者单位

    Department of Power Electronics, School of Mechatronics Engineering, University of Electronic Science and Technology of China, Chengdu, China;

    Department of Power Electronics, School of Mechatronics Engineering, University of Electronic Science and Technology of China, Chengdu, China;

    Department of Energy Technology, Aalborg University, Aalborg East, Denmark;

    Department of Energy Technology, Aalborg University, Aalborg East, Denmark;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Harmonic analysis; Microgrids; Power harmonic filters; Voltage control; Impedance; Reactive power;

    机译:谐波分析微电网电力谐波滤波器电压控制阻抗无功;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号