High-frequency oscillations caused by voltage source converters (VSCs) in current control timescale (less than 20 ms) have brought great challenges to the security and stable operation of the VSC-dominated power systems. However, relevant studies on this multi-input multi-output (MIMO) system still lack enough mechanism cognitions of its voltage amplitude/phase dynamics. Thus, this paper will propose a single-input single-output (SISO) equivalent method of this MIMO system to separately study its amplitude/phase dynamics. First, a linearized VSC model based on internal voltage motion equation in current control timescale is derived. This model can explicitly depict VSC's self-characteristic, which is suitable for multi-VSC voltage amplitude/phase dynamic analyses. Then, with reserving and converting the interactions of other outputs into one output, the MIMO system based on this VSC model can be equivalent into the amplitude motion and the phase motion, respectively. These two SISO systems are extremely convenient for engineers to study the mechanisms of the voltage amplitude/phase dynamics. Besides, this SISO equivalent method of the MIMO system can also be used to quantitatively analyze the interactions among the multi-VSC. Finally, the application of this method is illustrated in a single VSC system and the time domain simulations validate the correctness of the analyses.
机译:由电压源转换器(VSC)在电流控制时标(小于20 ms)中引起的高频振荡给以VSC为主导的电力系统的安全性和稳定运行带来了巨大挑战。但是,有关此多输入多输出(MIMO)系统的相关研究仍缺乏对其电压幅度/相位动态特性的足够机制认识。因此,本文将提出该MIMO系统的单输入单输出(SISO)等效方法,以分别研究其幅度/相位动态特性。首先,基于电流控制时标中基于内部电压运动方程的线性化VSC模型被推导。该模型可以明确描述VSC的自身特性,适用于多VSC电压幅度/相位动态分析。然后,通过保留其他输出的交互并将其转换为一个输出,基于该VSC模型的MIMO系统可以分别等效于幅度运动和相位运动。这两个SISO系统非常方便工程师研究电压幅度/相位动态机制。此外,MIMO系统的这种SISO等效方法还可以用于定量分析多VSC之间的相互作用。最后,在单个VSC系统中说明了该方法的应用,并且时域仿真验证了分析的正确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号