In this article, a new design for reversible air-air heat pumps is proposed. This design is not based on the refrigerant changeover, as is proposed by ASHRAE, but rather is based on the inversion of the air flow on the ducts. Thanks to this modification it is possible to use any air-air refrigeration machine for air conditioning as a reversible heat pump.rnThe new design is more efficient, especially when the building requires greater air quality and therefore a larger amount of outdoor air. It also increases its efficiency as the outdoor temperatures become more extreme.rnThis improvement will make it possible to use heat pumps, with acceptable performances, in more rigorous climates than those in which they are used today.
机译:在本文中,提出了一种可逆空气-空气热泵的新设计。这种设计并非基于ASHRAE提出的制冷剂转换,而是基于管道上气流的倒置。由于进行了这种修改,因此可以将任何空气空气制冷机用作可逆热泵来进行空调。rn新设计效率更高,尤其是当建筑物需要更高的空气质量并因此需要更多的室外空气时。随着室外温度变得越来越高,它的效率也随之提高。这种改进将使得在比今天使用的热泵更严格的气候条件下使用性能可接受的热泵成为可能。