The influence of natural ventilation on heating load and energy savings in a building with a double skinned envelope (DSE) was examined in this study. Field measurements and computer simulations were performed under various weather conditions. The DSE was effective for saving energy and creating natural ventilation rates under clear and partly cloudy skies. Due to insufficient irradiance, the DSE was not effective for reducing the heating load under overcast sky conditions. When natural airflow rates from the cavity space between internal and external skin to the indoor space were controlled, the southwest-facing DSE effectively reduced heating loads due to the accumulation of solar irradiance. Regression models showed that outdoor air temperature was the most significant factor governing variations in cavity temperature under all sky conditions. Computer simulations indicated that natural ventilation was practical at an appropriate supply temperature only when the sky ratio was less than 0.7. The airspace in cavity of the DSE provided additional natural ventilation rates to the indoor space and effectively reduced heating loads. Natural ventilation was available for 135 h during three winter months without consuming additional energy to heat the outdoor air. The heating load was reduced by the DSE ranged from 17.98% to 18.7% depending on the airflow control options for the cavity space.
机译:在这项研究中,研究了自然通风对带有双层外壳(DSE)的建筑物中的热负荷和节能的影响。在各种天气条件下进行了现场测量和计算机模拟。 DSE可有效节省能源并在晴朗和部分多云的天空下创造自然通风率。由于辐照度不足,DSE无法有效降低在阴天条件下的热负荷。当控制从内部和外部皮肤之间的空腔空间到室内空间的自然气流速率时,由于太阳辐照度的积累,面向西南的DSE有效地减少了热负荷。回归模型表明,在所有天空条件下,室外空气温度是决定型腔温度变化的最重要因素。计算机模拟表明,只有当天空比率小于0.7时,在适当的供应温度下自然通风才是可行的。 DSE腔内的空域为室内空间提供了额外的自然通风率,并有效减少了热负荷。在三个冬季的三个月中,自然通风时间为135小时,而无需消耗额外的能量来加热室外空气。 DSE将热负荷降低了17.98%至18.7%,具体取决于型腔空间的气流控制选项。

著录项

  • 来源
    《Energy and Buildings》 |2011年第9期|p.2118-2126|共9页
  • 作者单位

    Building Planning & Environment Research Division, Building & Urban Research Department, Korea Institute of Construction Technology, South Korea;

    Graduate School of Culture Technology, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, South Korea;

    Institute of Technology & Quality Development, Hyundai Engineering & Construction Co., Ltd., 102-4 Mabukodng Yonginsi, Kyeonggido 446-716, South Korea;

    Department of Housing & Interior Design, Yonsei University, Seoul, South Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    double skin envelope; heating load; energy savings; airflow control; natural ventilation;