Building envelope airtightness is important for residential energy use, occupant health and comfort. We analyzed the air leakage measurements of 134,000 single-family detached homes in US, using normalized leakage (NL) as the metric. Weatherization assistance programs (WAPs) and residential energy efficiency programs contributed most of the data. We performed regression analyses to examine the relationship between NL and various house characteristics. Explanatory variables that are correlated with NL include year built, climate zone, floor area, house height, and whether homes participated in WAPs or if they are energy efficiency rated homes. Foundation type and whether ducts are located outside or inside the conditioned space are also found to be useful parameters for predicting NL. We developed a regression model that explains approximately 68% of the observed variability across US homes. Of these variables considered, year built and climate zone are the two that have the largest influence on NL The regression model can be used to predict air leakage values for individual homes, and distributions for groups of homes, based on their characteristics. Using RECS 2009 data, the regression model predicts 90% of US houses have NL between 0.22 and 1.95, with a median of 0.67.
机译:建筑围护结构的气密性对于住宅的能源使用,乘员的健康和舒适性至关重要。我们使用归一化泄漏量(NL)作为度量标准,分析了美国134,000套单户独立屋的漏气量。天气数据援助计划(WAP)和住宅能效计划贡献了大部分数据。我们进行了回归分析,以检验NL与各种房屋特征之间的关系。与NL相关的解释变量包括建造年份,气候区,建筑面积,房屋高度以及房屋是否参与WAP或是否为能效等级房屋。还发现基础类型以及管道是位于条件空间的外部还是内部都是预测NL的有用参数。我们开发了一种回归模型,该模型可以解释美国房屋中约68%的观测变异。在考虑的这些变量中,建房年份和气候区是对NL影响最大的两个变量。回归模型可用于根据其特征预测单个房屋的漏气量以及房屋组的分布。使用RECS 2009数据,回归模型预测90%的美国房屋的NL在0.22至1.95之间,中位数为0.67。

著录项

  • 来源
    《Energy and Buildings》 |2013年第11期|616-625|共10页
  • 作者单位

    Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Mailstop 90R3058, Berkeley, CA 94720, USA;

    Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Mailstop 90R3058, Berkeley, CA 94720, USA;

    Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Mailstop 90R3058, Berkeley, CA 94720, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Blower door; Fan pressurization test; Normalized leakage; Air infiltration; Building envelope airtightness;