An improved adjoint network based algorithm is proposed for static security assessment. The main feature of the algorithm is the calculation of postcpntingency nodal voltages and phase angles in a noniterative fashion. This is achieved by adequate modeling of the generator (PV) nodes to account for the voltage regulator's response to line or generator contingencies. The tests show that the improved adjoint network method yields considerable savings in computing time for large power systems while retaining or improving the accuracy of the voltage phasor calculation as compared with the widely used 1P1Q method.
机译:提出了一种基于改进的伴随网络的静态安全评估算法。该算法的主要特点是以非迭代的方式计算出后节点电压和相角。这是通过对发电机(PV)节点进行适当建模来解决电压调节器对线路或发电机意外事件的响应而实现的。测试表明,与广泛使用的1P1Q方法相比,改进的伴随网络方法可节省大量电力系统的计算时间,同时保持或提高电压相量的计算精度。