The impact of PLL and VSC control parameters on the dynamic interactions between the AC and MTDC systems are discussed. A modularized method to incorporate the VSC-MTDC into transient stability programs (TSPs) is given. The proposed programs are validated via PSCAD simulation. Three results are obtained: (1) PLL has an insignificant effect on system stability. (2) The damping of MTDC grids is greatly affected by VSC control parameters. The inappropriate parameters would cause adverse effect on the damping performance of MTDC grids, resulting in large oscillation among DC voltages. However, these parameters have a negligible effect on small signal stability of AC systems. (3) Two forms of instability phenomena are found. One is caused by insufficient synchronizing torque; the other is caused by poorly damp of MTDC grids. As for the latter, it is the adverse interactions among the VSC controllers that cause the MTDC grids instability, thereby making the overall system easier to collapse. (C) 2016 Elsevier B.V. All rights reserved.
机译:讨论了PLL和VSC控制参数对AC和MTDC系统之间动态交互的影响。给出了将VSC-MTDC纳入暂态稳定程序(TSP)的模块化方法。通过PSCAD仿真验证了所提出的程序。得到三个结果:(1)PLL对系统稳定性的影响不大。 (2)MTDC电网的阻尼受VSC控制参数的影响很大。不适当的参数将对MTDC电网的阻尼性能产生不利影响,从而导致DC电压之间出现较大的振荡。但是,这些参数对交流系统的小信号稳定性影响可忽略不计。 (3)发现了两种形式的不稳定性现象。一是由于同步转矩不足引起的。另一个原因是由于MTDC网格的阻尼较差所致。对于后者,正是VSC控制器之间的不利相互作用导致MTDC电网不稳定,从而使整个系统更容易崩溃。 (C)2016 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Electric power systems research》 |2016年第12期|476-486|共11页
  • 作者单位

    Xi An Jiao Tong Univ, Sch Elect Engn, 28 Xianning West Rd, Xian, Peoples R China;

    Xi An Jiao Tong Univ, Sch Elect Engn, 28 Xianning West Rd, Xian, Peoples R China;

    Smart Grid Res Inst State Grid Corp China, Beijing, Peoples R China;

    Xi An Jiao Tong Univ, Sch Elect Engn, 28 Xianning West Rd, Xian, Peoples R China;

    Xi An Jiao Tong Univ, Sch Elect Engn, 28 Xianning West Rd, Xian, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    AC/MTDC system; PLL; Small signal stability; Rotor angle stability; Instability;

    机译:AC / MTDC系统;PLL;小信号稳定性;转子角稳定性;不稳定性;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号