首页> 外文期刊>Electric power systems research >Corrosion of copper armor caused by induced current in a 500 kV alternating current submarine cable
【24h】

Corrosion of copper armor caused by induced current in a 500 kV alternating current submarine cable

机译:500 kV交流潜艇电缆中诱导电流引起的铜铠装的腐蚀

获取原文
获取原文并翻译 | 示例
           

摘要

Alternating current (AC) is induced in armor because of electromagnetic induction. The induced AC flowing through the electrolyte?metal interface corrodes the armor, which accelerates submarine cable failure. Numerical simulation is performed to calculate the induced current density along a 500 kV submarine cable in the East China Sea, and the effect factors of the current are determined. Simulation experiments are conducted to study the corrosion of copper armor in artificial seawater at various AC current densities. The results reveal that the induced AC current densities can considerably increase the corrosion rates of copper armor. The max induced AC current densities are found to be located at the beginning and the end of the submarine cable. Crossconnection can effectively reduce the induced AC current density of the armor and thus reduce its corrosion rate (From 1.57 to 0.15 mm/a). Cross-connections are required at both ends of a submarine cable to reduce armor corrosion. For cross-connected submarine cables, the cable length, cable spacing, and resistivity of the outer serving have a negligible effect on the corrosion rate. The load current, defect diameter, and environmental resistivity have a considerable effect on the current density.
机译:由于电磁感应,在装甲中引起交流电流(AC)。流过电解质的诱导交流件缠绕金属界面腐蚀盔甲,其加速了潜艇电缆故障。执行数值模拟以计算沿东海500 kV潜艇电缆的诱导电流密度,并确定电流的效果因素。进行仿真实验,以研究人工海水铜铠装在各种交流电流密度。结果表明,诱导的AC电流密度可以大大增加铜铠装的腐蚀速率。最大诱导的AC电流密度被发现位于潜艇电缆的开头和末端。交叉连接可以有效地降低铠装的诱导的AC电流密度,从而降低其腐蚀速率(从1.57到0.15mm / a)。潜艇电缆的两端都需要交叉连接,以减少盔甲腐蚀。对于交叉连接的潜艇电缆,电缆长度,电缆间距和外部服务的电阻率对腐蚀速率可忽略不计。负载电流,缺陷直径和环境电阻率对电流密度具有相当大的影响。

著录项

  • 来源
    《Electric power systems research》 |2021年第6期|107144.1-107144.10|共10页
  • 作者单位

    China Univ Petr Natl Engn Lab Pipeline Safety MOE Key Lab Petr Engn Beijing Key Lab Urban Oil & Gas Distribut Technol Beijing 102249 Peoples R China;

    China Univ Petr Natl Engn Lab Pipeline Safety MOE Key Lab Petr Engn Beijing Key Lab Urban Oil & Gas Distribut Technol Beijing 102249 Peoples R China;

    Univ Sci & Technol Beijing Natl Ctr Mat Serv Safety Beijing Peoples R China;

    China Univ Petr Natl Engn Lab Pipeline Safety MOE Key Lab Petr Engn Beijing Key Lab Urban Oil & Gas Distribut Technol Beijing 102249 Peoples R China;

    China Univ Petr Natl Engn Lab Pipeline Safety MOE Key Lab Petr Engn Beijing Key Lab Urban Oil & Gas Distribut Technol Beijing 102249 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ac corrosion; Submarine cable; Induced ac; Copper armor;

    机译:交流腐蚀;潜艇电缆;诱导AC;铜盔甲;